HEARTH MOUNT INSTALLATION

HEARTH MOUNT INSTALLATION

Vertical Cap

Storm Collar

Chimney Cap

Figure 17

Pellet

Liner NPI40 INSTALLATION

Flue Cover

17

NPI40 INSTALLATION

MINIMUM CLEARANCES TO COMBUSTIBLES

Side wall to unit

8"

Maximum mantel depth

10"

Mantel to top of unit

8"

Top facing to unit

6 3/8"

Side facing to unit

6"

Floor protection*

6"*

Clean-outMINIMUM CLEARANCES TO COMBUSTIBLES tee MINIMUM MANTEL CLEARANCES

Pellet

 

Figure 18

Vent

 

* Floor Protection: Minimum 6" in front of door and to either side.

 

 

 

6”

MINIMUM MANTEL CLEARANCES

 

 

 

MIN

 

Floor

PRIOR TO INSTALLATIONINSTALLATIONINTOAMASONRYFIREPLACEREAR TO TOP VENT CONVERSION INSTRUCTIONSProtection Bring outside air

to the stove Outside Air

(Recommended)

PRIOR TO INSTALLATION

Clean all ashes out of the inside of the fi replace. Make sure that the chimney and fi replace are free of cracks, loose mortar, cresote deposits, blockage or other signs of deterioration. If necessary, have any repair work done by a qualifi ed professional before installing the insert.

Do not remove bricks or mortar from the fi replace.

INSTALLATIONINTOAMASONRYFIREPLACE

1.Remove the fi replace damper or fasten it permanently open.

2.Measure the throat of the fi replace and mark this shape on a piece of 24 gauge sheet metal (fl ue cover). Cut a hole sized for the pellet liner to lie directly below the fi replace fl ue opening. Allow two inches of material for a fl ange on all sides and cut to these mea- surements. Bend down the fl anges. If you have never done this before, it might be a good idea to make a cardboard pattern and test it first. fasten this flue cover in position as high as possible with two masonry screws per side through the fl anges into the fi replace.

3.If you plan on connecting outside air it is recommended to do so at this time.

4.Connect the pellet vent with a clean out tee to the back of the stove. Refer to manufacturer's installation instructions and the "General Venting Section".

5.Run a liner down the chimney and connect to tee.

6.Position the stove in it's fi nal location.

7.Pull the excess length of liner out through the top of the chim- ney. Trim the excess liner, install the cap and cap the chimney.

Figure 19

REAR TO TOP VENT CONVERSION INSTRUCTIONS

NOTE: The insert is factory shipped in a rear vent confi guration.

1.To vent exit vertically, remove the two screws holding the exhaust cover. NOTE: Be

careful not to damage the Figure 20

gasket.

Exhaust Cover

2. Remove the two

 

screws holding the

 

exhaust tube (NOTE: Be careful not to damage the gasket).

3.Attach the exhaust tube and gasket in the vertical position.

4. Attach the exhaust

Exhaust Tube

cover and gasket over the

 

horizontal exit.

 