INSTALLATION INTO A MASONRY FIREPLACE

19

INSTALLATION INTO A MASONRY FIREPLACE

PRIOR TO INSTALLATION

Figure 22

 

 

Stand-offs (See Dimensions on page 7) may be removed to fi t the insert into the fi replace.

When installing the insert into a masonry fi replace, do not remove any bricks or masonry. If necessary, the damper plate may be removed from the smoke shelf, to accommodate the chimney liner. Do not weaken the structure, or reduce the protection for combus- tible materials to less then that required by the National Building Code.

A non-combustible hearth must cover the fl ooring underneath, as well as extend a minimum of six inches in front and to both sides of the heater.

Clean all ashes out of the inside of the fi replace. Make sure that the chimney and fi replace are free of cracks, loose mortar, creo- sote deposits, blockage or other signs of deterioration. If neces- sary, have any repair work done by a qualifi ed professional before installing the insert.

Do not remove bricks or mortar from the fi replace.

Install fl oor protection if necessary.

INSTALLATION INTO A MASONRY FIREPLACE

HORIZONTAL VENT INSTALLATION

1.If you plan on connecting outside air it is recommended to do so at this time.

2.A hole must be made in the back of the fi replace to accom- modate the pellet vent. Connect the pellet vent to the back of the stove and position in place. Refer to manufacturer's installation instructions and the "General Venting Section".

3.Connect the vent cap to vent.

VERTICAL LINER INSTALLATION

1.If you plan on connecting outside air it is recommend to do so at this time.

2.Remove the fi replace damper or fasten it permanently open.

3.Measure the throat of the fi replace and mark this shape on a piece of 24 gauge sheet metal (fl ue cover). Cut a hole sized for the pellet liner to lie directly below the fi replace fl ue opening. Allow two inches of material for a fl ange on all sides and cut to these mea- surements. Bend down the fl anges. If you have never done this before, it might be a good idea to make a cardboard pattern and test it first. fasten this flue cover in position as high as possible with two masonry screws per side through the fl anges into the fi replace.

4.Convert the exhaust tube to a vertical application. See "Rear to Top Vent Conversion Instructions" section.

5.Run a liner down the chimney and connect to the exhaust tube. Refer to manufacturer's installation instructions and the "General Venting Section".

6.Position the insert in it's fi nal location.

7.Pull the excess length of liner out through the top of the chim- ney. Trim the excess length and cap the vent.

W415-0616 / B / 02.18.08