Napoleon Fireplaces NPI40 General Installation, Specifications, Epa Compliance, Heater Placement

Models: NPS40 NPI40

1 40
Download 40 pages 42.1 Kb
Page 10
Image 10
SPECIFICATIONS

10

SPECIFICATIONS

Electrical Rating

115 Volts, 3.6 Amps, 60Hz

Watts During Start-Up Se-

400 (approximately)

quence

 

 

Watts During Operation

180 (approximately)

 

 

 

NPS40 Width

22

3/8"

 

 

 

NPS40 Height

30

1/2"

 

 

 

NPS40 Depth

26

5/8"

 

 

Weight

210 Pounds

 

 

 

Exhaust Collar

3"

 

 

 

 

Intake Collar

2"

 

 

 

NPS40 Hopper Cap.

55 Pounds

 

 

 

NPI40 Hopper Cap.

45

Pounds

 

 

EPA

Exempt

 

 

Burn Rate**

1.0 to 5.0 (Pounds Per Hour)

 

 

BTU/h**

8500 to 42500

 

 

Minimum Fireplace Opening

Front: 22 1/2* W x 20 5/8 H x

Size

14

1/4 D

 

Back: 20 3/8 W

*In order to install fl ashing fl ush to fi nished wall and centered within the opening the front opening of the fi replace or enclosure must be 32 5/8" wide.

EPA COMPLIANCE

This heater is EPA exempt from Phase II requirements, but has been tested for emissions using EPA test methods by Warnock Hersey.

GENERAL INSTALLATION

PLANNING YOUR INSTALLATION

!WARNING

READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO

FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.

Check with local building offi cials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation.

Before installing we recommend placing the heater outside and load 5 pounds of pellets inside the hopper. Plug the heater in and let it run on HIGH until the pellets run out. This will cure the paint and burn off the oils on the steel, there by minimizing any smell inside the home.

HEATER PLACEMENT

Have an authorized Napoleon® dealer install the heater. If you install the heater yourself, have your dealer review your installation plans and/or installation.

Draw out a detailed plan of the installation including dimensions and verify the dimensions with the requirements listed in this manual.

For built-in enclosures, when determining the location of the heater, locate the wall studs (for horizontal penetrations). You may wish to adjust the heater position slightly to ensure the vent does not intersect with a framing member.

Heater must be positioned so that no combustibles are within, or can swing within (e.g. drapes, doors), 48" of the front of the heater. If the heater is placed in a location where the ceiling height is less than 7' above the base of the heater, the installation must follow the requirements in the section "Alcove Installations Require- ments"

INSTALLATION OPTIONS

NPS40:

To install in a Residential or Mobile Home see the section "Mobile

Home Requirements".

For alcove installations see the section "Alcove Installation

Requirements".

For horizontal vent or vertical vent see the section "General Vent- ing".

See the section "Outside Air" for this option.

NPI40:

The insert can be adapted to vent out the rear or vertically.

To install as an insert into an existing masonry fi replace factory built fi replace or a built in combustible enclosure see Insert Instal- lation.

FLOOR PROTECTION REQUIREMENTS

NPS40:

The heater must be installed on a non-combustible fl oor protector extending the full depth of the heater and extending a minimum 6" in front and on either side (minimum .018" thick - 26 gauge).

The fl oor protector must extend under and 2" beyond each side and rear of a "Tee" (if used).

NPI40:

In the case of the NPI40, the fl oor protector must have a R-value of 0.4 hr ft²°F

BTU

W415-0616 / B / 02.18.08