DAILY (WHENEVER USING THE HEATER)
Figure 39
Figure 38

26

DAILY (WHENEVER USING THE HEATER)

CONTINUED

MAKE SURE PELLETS ARE NOT PILING UP

If the pellets build up over the burn pot, turn the pellet feed switch to "OFF".

If the fl ames seem to be coming only from the sides, or are or- ange/black, turn the heater off and check for build up of pellets.

The most likely causes are:

1.Feed rate has been set to maximum for an extended period of time. Turn feed rate to optimum.

2.The door, glass, or ash pan is open or has an air leak.

3.The burn pot requires cleaning.

4.The exhaust system requires cleaning.

5.The heater requires adjustment.

6. Poor pellet quality

CLEANING THE BURN POT

!WARNING

Make certain the heater has fully cooled (approximately 25 minutes) before opening the door and conducting service.

To clean the burn pot, open the door and knock away any debris on the burn pot. If se- verely clogged, remove the burn pot to gain bet- ter access.

If removing the burn pot set aside on a non-combustible surface. See Figure 39. Once

removed, discard all material that has accumulated in the burn pot.

BI-WEEKLY (OR EVERY 10 BAGS OF

PELLETS)

VACUUM FIREBOX

The more frequently you clean out the fl y ash, the more effi cient your heater will burn.

!WARNING

The fire box becomes very hot during operation. Let the heater cool completely before conducting service.

1.Open the viewing door. See Figure 35 and 36

2.Lift the burn pot out and set aside on a non-combustible surface. See Figure 39. Remove the right and left louvres by lifting the louvres up and out of the fi rebox setting them on a non-combustible surface.

Figure 41

LOUVRES MAKE SURE PELLETS ARE NOT PILING UP

FIREBOX

AIR HOUSING

 

3.Vacuum out the fi rebox, louvres, air housing and burn pot of all fl y ash.

Make certain that all openings are clear of any build up of ash from the ledge below the burn pot.

Re-install the burn pot ensur- ing it sits level in the heater. Also must ensure the ignitor and the burn pot locating notch line up when reinstalling the burn pot.

LOCATING NOTCH

IGNITOR

Figure 42

4.Replace the louvres and burn pot, latch the viewing door closed and close both side doors.