Table 5-2. ifxdeploy.conf File Parameters (continued)

 

+

 

 

 

 

 

Example of Value Setting

+

Parameter

Description

(Uncommented Line)

+

 

 

 

INFORMIXPASSWORD

Password for user informix

INFORMIXPASSWORD password

+

 

on the target computer. Sets

 

+

 

password to what you enter

 

+

 

as a value if no user

 

+

 

informix exists on the

 

+

 

computer.

 

+

 

 

 

SYSTEM

Sets whether the deployed

SYSTEM 1 (this directs instance to

+

Note: This parameter

instance will log on to

log on as local system account but

+

is for Windows only.

Windows as local system

user informix is created) SYSTEM 2

+

 

account. The default value is

(this deploys instance without

+

 

0 (IDS logs on as user

creation of user informix)

+

 

informix).

 

+

 

 

 

LOGFILE

Sets the full path name for

LOGFILE c:\my_log.txt

+

 

the log file of the

 

+

 

deployment utility’s errors

 

+

 

and messages.

 

+

 

 

 

LOGLEVEL

Sets amount of information

LOGLEVEL 5

+

 

to write to log. Refer to the

 

+

 

ifxdeploy.conf file for

 

+

 

permissible values.

 

+

 

 

 

SILENT

Sets whether or not the

SILENT 1 (no console output)

+

 

utility displays console

 

+

 

output while it is running.

SILENT 0 (displays console output)

+

 

 

 

FORCE

Overwrites existing

FORCE 0 (Does not overwrite)

+

 

environment variable and

 

+

 

onconfig file settings of the

FORCE 1 (Overwrites existing

+

 

target computer.

settings)

+

 

 

 

INSTALLDRIVE

Specifies the directory in

INSTALLDRIVE C

+

Note: This parameter is

which the deployed

 

+

for Windows only.

instance’s dbspaces will be

 

+

 

created on Windows.

 

+

 

 

 

ROOTPATH

Sets the location of the root

default path:drive:\ifmxdata\

+

 

dbspace.

server_name\rootdbs_dat.000

+

 

 

 

WIN6432

Set this to 1 if installing

WIN6432 1

+

Note: This parameter

32-bit IBM Informix

 

+

is for Windows only.

Dynamic Server on 64-bit

 

+

 

Windows.

 

+

 

 

 

BEGIN ONCONFIG . . .

Specify values for any

BEGIN ONCONFIG

+

END ONCONFIG

configuration file

LOCKS 10000

+

 

parameters. Enter each

END ONCONFIG

+

 

parameter and value exactly

 

+

 

as they would be entered in

 

+

 

the onconfig file.

 

+

 

Can be used to overwrite

 

+

 

specific onconfig file

 

+

 

parameter values or instead

 

+

 

of providing an onconfig

 

+

 

file.

 

+

 

 

 

 

 

 