Kenmore 170, 275 installation manual Pressure Test / Check for Leaks, House Main, Shutoff Valves

Page 18

li!i ! ::i:i ! ::i:i ! :i SECTION 3

STEP BY STEP GUIDES TO INSTALL

E. PRESSURE TEST / CHECK FOR LEAKS

[] CAUTION:

HOUSE MAIN

WATER

 

SHUTOFF

VALVES

To avoid water or air pressure damage to soft- ener inner parts, and to flush pipe chips or other residue from the water pipes, be sure to

do the following steps exactly as instructed.

Look at the picture in FIG. 15 showing your kind of bypass valve(s).

Shutoff _)

_

_ Water

Shutoff

_1_

Fully

open two cold,

soft

water

faucets

nearby

 

the softener.

 

 

 

 

 

 

 

_Jl

Place

bypass

valve(s)

in

"bypass"

position.

On

 

a single valve,

slide the stem inward

to

bypass.

 

On a 3-valve

system,

close the

inlet

and

 

outlet

 

valves and open the bypass valve.

 

 

 

_ Fully open the house main water pipe shutoff

valve (closed in step 1, page 3-1). Observe steady water flow from both open faucets.

_Jl Place bypass valve(s) in "service", EXACTLY as follows: Keep soft water faucets open.

O SINGLE BYPASS VALVE: SLOWLY, slide pull

the valve stem outward toward service, pausing several times to allow the softener to pressurize slowly.

@3-VALVE BYPASS: Fully close the bypass valve and open the outlet valve. SLOWLY, open the

inlet valve, pausing several times to allow the

softener to pressurize slowly.

I_J After about three minutes, open a hot water

faucet for about one minute, or until all air is

expelled, then close.

_ Close both cold water faucets.

_1 Check your plumbing work for leaks and fix right away if any are found. Be sure to observe

previous caution notes.

Bypass valve(s) should always remain in soft water service position. Position in bypass only if needed for softener repairs.

SINGLE BYPASS

PULL STEM

OUTWARD

FOR

SERVICE

Push

Inward

For

Bypass

 

 

3 - VALVE BYPASS

 

 

 

 

 

Bypass

 

 

 

 

Valve

FOR

SERVICE

 

 

close

bypass

valve

Outlet r

 

open inlet & outlet valves

 

Valve k2

Inlet

 

 

 

 

 

 

 

FOR

BYPASS

 

Valve

 

 

open

bypass

valve

 

 

close inlet & outlet valves

 

 

3-7

Deluxe Valve

Image 18
Contents Installation Manual Save this ManualIntroduction Plan Your Installation Restart the Water HeaterBefore Installing Checks & Tests Safety GuidesUnpacking the Water Softener Parts DescriptionsSmall Parts Before Installing Checks & Tests Water System TestsWhere to Install the Water Softener HeaterTOOLS, Pipe and FITTINGS, Other Materials Needed Out fittings included with the softener arePipe and FITTINGS, Plan Drawing ElectricalI1UTypical Soldered Copper or PVC in and OUT Pipes to Softener Deluxe Valve ModelsAdaptoric,o? Typical Threaded in and OUT Pipes to SoftenerOr the Inlet Outlet Threaded Assemble INLET-OUTLET ADAPTORS, or Plastic Bypass ValveGO to Inlet and Outlet Threaded Adap GO toInstalling Holding Clips Bypass Valve Turned DownwardInstall 3-VALVE Bypass Installing 3 Valve Bypass and PipesValve Bypass Move the Softener Into Place Move Softener Into PlaceTypical Soldering Connections Connect Valve and Salt Tank Drains Connect the Valve Drain HoseOl Connect Valve and Salt Tank Drains Connect Salt Tank Overflow TU- BingPressure Test / Check for Leaks House MainShutoff Valves Electrical Power Outlet for Your Softener To Electrical PowerInstall Grounding Wire Between Softener in and OUT Pipes Grounding / ConnectPlug Transformer Connecting Install CoversGrounding / Connect to Electrical Power Restart Water HeaterWith High Performance valve High Performance Valve Before Installing Checks & Tests Safety Guides Ring Parts Descriptions Small PartsWater System Tests Where to Install the Water Softener TOOLS, Pipe and FITTINGS, Other Materials Needed YO UR HO USE MAI N Water %--------.. Maine Threaded adaptor Install Sears Bypass Valve and / or Assemble INLET-OUTLET ADAPTORS, or Plastic Bypass ValveInstalling Holding Clips Bypass Valve Turned Downward Install 3-VALVE Bypass Locate Water Softener Connect PipesStep by STE P G Uides to Install Connect Valve and Salt Tank Drains= Connect Valve and Salt Tank Drains Connect Salt Tank Overflow TUHouse Main Water Install Grounding Wire Between Softener in and OUT Pipes Cold Water Pipe Grounding Meter Jumper WireInstall Covers Restart the Water Heater