Plumbing Connections

CAUTION : The FlashGard-HP Reverse Osmosis Water Filtration System requires a minimum 60 psi (413.7 kPa) inlet water pres- sure. To ensure adequate inlet water pressure, it is recommended that the system be plumbed after the beverage booster pump but before the beverage water filtration system. Refer to Figure 2 for proper tubing connections.

CAUTION: Use care in routing the tubing to ensure that there are no bends or kinks.

CAUTION

To reduce the risk associated with property damage due to water leakage:

Before starting installation, shut off main water supply and drain pipes.

Installation and Use MUST comply with all state and local plumbing codes.

Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100°F (37.8°C).

Do not install if water pressure exceeds 100 psi (690 kPa). If your water pressure exceeds 80 psi (552 kPa) you must install

a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

Do not install where water hammer conditions may occur. If water hammer conditions exist, you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.

Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing.

Do not install unit if collet is missing. Contact your Sales Representative if collets are missing from any fittings.

On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.

Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtightening occurs.

Do not install in direct sunlight or outdoors.

Ensure all tubing and fittings are secure and free of leaks.

1)Shut off water supply and/or beverage water booster pump.

2)Route the water supply or booster pump to the RO system’s inlet water valve.

3)Assemble the water sample valve assembly (Refer to Figure 2A).

a.Push small piece of tubing into tee.

b.Push opposite end of the small piece of tubing into 1/4” ball valve.

c.Push remaining section of the blue tube into the other end of the ball valve.

4)Cut a piece of the 3/8” blue tubing (included). Connect one end to the outlet tee on the RO system and the other end to one side of the Water Sample Valve Assembly (See Figure 2).

5)Run length of tubing from the other end of the Water Sample Valve Assembly to the inlet of the steamer. See Figure 2.

Tank Shut-Off Valve

 

Inlet Water Valve

 

 

1/4 x1/4

 

3/8” Blue Tubing

Stem x Barb Adapter

 

 

 

 

To Steamer

Feedwater from

 

 

Beverage Booster

 

Water Sample

System

 

Valve Assembly

 

 

(See Figure 2A)

Prefilter Cartridge

 

Reverse Osmosis (RO) Membrane

P/N 55706-08

 

 

P/N 55987-15

 

 

SFC Tubing

 

 

 

 

Schrader Air Valve

1/4” Red Tubing

 

 

(To Drain)

Figure 2

 

 

 

3/8” Reducing Tee

Small Piece of 1/4” Blue Tubing

1/4” Ball Valve

Remaining Piece of Tubing

Figure 2A

5

Image 5
Contents 3M Water Filtration Products To reduce the risk associated with choking DamageTo reduce the risk of physical injury To reduce the risk associated with back strainProduct Dimensions Parts ListMounting Plumbing Connections RO Membrane Cartridge Replace every 24-36 months Using Push-In FittingsSystem Start-Up Tank Pressure Check Replacement PartsProblem Cause Solution Troubleshooting GuidePage Page Page Cuno Incorporated

FSTMO75 specifications

The 3M FSTMO75 is a versatile and innovative product that stands out in the realm of transportation safety and visibility solutions. Designed primarily for use in various applications including transportation, construction, and emergency response, the FSTMO75 offers exceptional performance and reliability.

One of the main features of the 3M FSTMO75 is its advanced retroreflective technology, which significantly enhances visibility in low-light conditions. This is particularly crucial for vehicles and equipment operating in potentially hazardous environments. The retroreflection effect ensures that light from headlights or other sources is redirected back toward the source, making objects and personnel more noticeable to drivers and operators. This feature greatly contributes to overall safety by reducing the risk of accidents.

The FSTMO75 boasts a durable construction, designed to withstand harsh environmental conditions. It is built with high-quality materials that resist wear and tear, ensuring longevity even in rugged settings. This characteristic makes it an ideal choice for use in construction zones, where durability is essential due to exposure to heavy machinery and unpredictable weather.

Additionally, the 3M FSTMO75 incorporates a user-friendly design that facilitates easy application. Whether applied to vehicles, road signs, or equipment, the adhesive backing ensures secure attachment, while its flexibility allows it to conform to various surfaces. This adaptability makes it suitable for diverse applications, from marking vehicles to enhancing the visibility of road hazards.

Another noteworthy characteristic of this product is its ability to provide bright and vibrant colors. The fluorescent options available within the FSTMO75 product line enhance visibility even in daylight, increasing the likelihood that individuals or equipment will be seen from a distance. This is particularly beneficial in public works scenarios where safety is paramount.

In conclusion, the 3M FSTMO75 is a cutting-edge solution for enhancing visibility and safety in various environments. With its advanced retroreflective technology, durable construction, user-friendly application, and vibrant color options, it sets a high standard in the market. Whether in construction, emergency response, or transportation, the FSTMO75 offers essential benefits that prioritize safety and efficiency for users on the job.