Star Knob
Foot Switch (14): Press On, release Off | Direction Lever |
| Center: neutral; Push down: slow reverse, Fast |
| reverse direction. |
Attaching Guide Spring (48)
While following these procedures, it may be helpful to refer to the Parts List and Assembly Drawings located at the end of this manual.
1.Unplug the Power Cord from the electrical outlet.
2.Pull up on the Direction Lever
3.Loosen Tension Knob
4.Slide the Guide Spring (48) over the cable and onto the Adapter
5.Pull out and align the Spring Loaded Pin (46) on the Guide Spring, with the hole in the Adapter
6.Retighten Tension Knob
Select and Attach Proper Cutting Tool
There are four Cutting Tools included with the Drain Cleaner. Select the appropriate tool for the cleaning job and attach to Cable (39a). Each is described in the table below.
Cutter Tool | Application |
Arrow Cutting Head (58) | Starting tool for cutting and scraping |
|
|
Auger Bulb (59) | Starting tool to remove loose objects |
|
|
Finishing tool for grease stoppages and scraping pipe walls | |
|
|
Starting / Finishing tool to remove loose objects and scraping pipe walls | |
|
|
1.Select the desired cutter tool and insert it into the female connector located at the end of the Cable (39a). It is recommended to start with the Arrow Cutting Head (58) or Au- ger Bulb (59). Once the drainpipe is opened, then use the
REV 08e
SKU 93188 | For technical questions, please call | Page 10 |