Installation | Aerada 1000/1100 Series |
9Mount mixer handle (only for faucets with external mixer)
Result: The faucet is now mounted.
A - Setting Cleaning Mode
Setting the cleaning mode will make the faucet inactive for 90 seconds.
1Enable “Manual Setting” Mode
> See “Enabling Manual Setting Mode” section
2Fully cover sensor with hand, until water flow stops. (This takes 5 seconds.)
3Remove hand.
Result: The Cleaning Mode is now active. For the next 90 seconds, the faucet will be inactive.
B - Setting Normal Mode
Setting the normal mode will allow the faucet to activate only when it senses a hand presence.
1Enable “Manual Setting” Mode
> See “Enabling Manual Setting Mode” section
2Fully cover sensor with hand. Water flow stops after 5 seconds - Continue to hold on for one (1) additional water pulse.
3Remove hand.
Result: Normal Mode is now activated.
C - Setting Metering Mode (10 seconds)
Setting the metering mode will allow the faucet to activate for a full 10 seconds after if senses a hand presence.
1Enable “Manual Setting” Mode
> See “Enabling Manual Setting Mode” section
2Fully cover sensor with hand. Water flow stops after 5 seconds - Continue to hold on for another two (2) additional water pulses.
3Remove hand.
Result: Metering Mode is now activated for 10 seconds.
Bradley Corporation • | 5/21/08 | 7 |