Aerada 1000/1100 Series | Installation |
CARE AND MAINTENANCE INSTRUCTIONS
The following instructions are described in this section:
•Activating Cleaning Mode
•Replacing Battery
•Cleaning or Replacing Inlet Filter
•Adjusting Water Temperature (Internal Mixer)
•Adjusting Hot Water Limiter (External Mixer)
•Cleaning or Replacing Aerator
Activating Cleaning Mode
In order to set the cleaning mode, the faucet needs to be have been set once into the “Manual Setting” mode. See “Manual Setting” instructions. When cleaning mode is activated, the faucet will be inoperable for 90 seconds.
1Fully cover sensor with hand, until water flow stops. (This takes approximately 5 seconds.)
2Remove hand.
Result: Cleaning Mode is now activated.
Replacing Battery
A traditional lavatory faucet is shown as an example. These instructions apply to all DC models.
Prerequisites
•Battery is low (LED is lit)
•New 6 V Lithium battery
1Remove
2Remove mixer handle (for faucets with external mixer only)
3Remove housing vertically.
4Remove used battery from battery holder and recycle.
5Insert new battery.
> LED lights up for 1 second
6Mount housing vertically.
12 | 5/21/08 | Bradley Corporation • |