Aube Technologies TI034-3W manual Installation and User Guide

Page 1

nApplications

TI034-3W

Installation and User Guide

Programmable Wall Switch

pPower-on

The TI034-3W switch can be used in a single-pole or 3-way installation with the fol- lowing types of lighting:

Incandescent

Halogen

Low-voltage halogen with transformer

Fluorescent

The TI034-3W switch cannot be used with a load below 40 W or above 500 W.

oInstallation

nCut power at the circuit breaker to avoid electric shock.

nPry the switch door open from the bottom using a small screwdriver.

oEnsure the ON/OFF selector is set to ON.

pReset the switch using a paper clip. 0:00 will

flash.

If the display is blank:

Ensure the ON/OFF selector is properly engaged in the ON position. Push it to the right using a small screwdriver.

Reset

Control (4)

On/Off selector

oRemove the existing switch. (For a 3-way installation, identify and label the wire that is connected to the “common” screw.)

pInstall the new switch (refer to the appropriate section below).

qApply power at the circuit breaker.

NOTE A: The white wire is not the neutral wire but the wire going to the load.

SINGLE-POLE INSTALLATION

120 VAC

Line

 

Neutral

See NOTE A

 

120 VAC

Line

Neutral

Connect wires "2" and "C" of TI034-3W to the line (120 V) wire.

EXISTING 3-WAY INSTALLATION

120 VAC

See NOTE A

Red

Jumper

Red

3-wire cable

 

 

Connect wire "C" on the TI034-3W to the "common" wire, identified when removing the old switch. Connect the other two TI034-3W wires to the two remaining wires.

At the other 3-way switch, connect the jumper wire between the "common" screw and the screw where wire "1" of the TI034-3W is connected.

NEW 3-WAY INSTALLATION

120 VAC

See NOTE A

 

The jumper wire is not required in this installation. A single-pole switch can be used as the other switch in a 3-way installation.

TI034-3W

If the programmable switch controls a lamp equipped with a built-in On/Off switch, ensure the lamp switch is set to On.

Ensure the light bulb is not burned out and is tightly screwed in its socket..

EXISTING 3-WAY INSTALLATION

If either switch does not work properly, rewire the jumper between the "common" screw and the other screw.

WARNING: Before replacing the light bulb, place the ON/OFF selector in the OFF position. Failure to do so might damage the switch.

qSelecting the Operating Mode

The programmable switch has 2 operating modes: manual (MAN) and automatic (AUTO). To switch mode, press the switch for 3 seconds.

Manual Mode

The programmable switch operates as a regular switch. Briefly press the switch door to turn the lights On or Off. The mode (MAN) and state (ON or OFF) are displayed.

Automatic Mode

The programmable switch follows the programmed schedule. The mode (AUTO), state (ON or OFF) and current program number are displayed.

To temporarily override the programmed schedule, briefly press the switch door. The new state (ON or OFF) will flash to show that the state is temporary. The override remains in effect until you press the switch door again or until the beginning of the next program.

rSetting the Clock

NOTE: The switch displays the time in 24-hour format by default or following a reset.

nTo switch between 12-hour format and 24-hour format, proceed as follows:

a)Press one of the control buttons to ensure the MAN or AUTO indicator is dis- played.

b)Press the MIN and HOUR buttons simultaneously and brieftly (0:00 display = 24-hour; 12:00 display = 12-hour ).

oSet the time using the HOUR and MIN buttons. For the 12-hour time format, if you are setting an afternoon time, ensure PM appears on the screen.

pPress one of the control buttons or close the switch door to return to normal opera- tion.

sDaylight Savings Time

This procedure configures the switch in daylight savings time or in normal/standard time.

nPress the CODE button four times.

oPress the MIN button to switch between nor and Ad.

nor

Standard time / Normal time / Winter time

 

 

Ad

Daylight savings time / Advanced time / Summer time

 

 

pPress one of the control buttons or close the switch door to return to normal opera- tion.

400-034-001-D13/3/071/2

Image 1
Contents TI034-3W Installation and User GuideSunset/Sunrise Program TroubleshootingProgramming the Schedule Addendum TI034-3W / TI035Service à la clientèle WarrantyGarantie Garantia

TI034-3W specifications

Aube Technologies has made a significant impact in the HVAC and building automation sectors with its innovative products, and the TI034-3W thermostat stands out among them. This device is designed specifically for controlling heating systems, particularly in residential and small commercial buildings. Its sleek design and advanced functionalities make it a popular choice among facility managers and homeowners alike.

One of the main features of the TI034-3W is its compatibility with various heating systems, including electric baseboards, convectors, and infrared heaters. This versatility allows it to be used in diverse applications, providing effective temperature control tailored to individual needs. The thermostat operates with a wide voltage range, making it suitable for most electrical configurations.

A primary characteristic of the TI034-3W is its ability to provide precise temperature control. The device uses advanced sensors that monitor ambient temperature with high accuracy, ensuring that the desired comfort level is maintained. Users can set specific heating schedules to optimize energy consumption, tailoring the system to match their daily routines. This feature not only enhances comfort but also promotes energy efficiency, an essential factor in today’s eco-conscious landscape.

The technology behind the TI034-3W includes an intuitive user interface that allows for easy programming and management of settings. The backlit display ensures clear visibility, even in low-light conditions, making it user-friendly. Furthermore, the digital interface provides real-time feedback on the system status, including current temperature and set points.

Another significant aspect of the TI034-3W is its built-in energy-saving features. The thermostat can automatically adjust the temperature settings based on user-defined patterns, which helps minimize energy wastage. This is particularly beneficial in terms of reducing utility bills and achieving lower carbon footprints.

In addition to its energy-saving capabilities, the TI034-3W incorporates safety features that enhance its reliability. It is equipped with a built-in sensor to prevent overheating, ensuring safe operation. The compact design makes it easy to install in various settings, while the durable construction guarantees longevity.

Overall, the Aube Technologies TI034-3W is a sophisticated and efficient heating control solution that merges comfort, energy savings, and user-friendly technology. Its features make it a worthwhile investment for anyone looking to enhance their heating management system with a reliable and effective thermostat.