Frigidaire FRA065AT7, FRA106CV1 important safety instructions Before You Call, Occurrence Solution

Page 12

Before You Call

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

OCCURRENCE

SOLUTION

 

 

 

 

Air conditioner will not operate.

Wall plug disconnected. Push plug firmly into wall outlet.

 

 

 

 

 

 

 

Plug Current Device Tripped. Press the RESET button.

 

 

 

 

 

 

 

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

 

 

 

 

 

 

 

Control is OFF. Turn Control ON and set to desired setting.

 

 

Air from unit does not feel cold

Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above

enough.

60°F (16°C).

 

 

 

Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.

 

 

 

 

 

 

 

Reset to a lower temperature.

 

 

 

 

 

 

 

Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to

 

 

 

restart when set in the COOL mode.

 

 

Air conditioner cooling, but room

Outdoor temperature below 60 O F (16 OC). To defrost the coil, set FAN ONLY mode.

is too warm - ice forming

 

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY

on cooling coil behind decorative

mode.

front

Temperature is set too low for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then,

 

 

 

 

 

 

set temperature to a higher setting.

 

 

 

Air conditioner cooling, but room

Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.

is too warm - NO ice forming on

 

Temperature is set too high. Set temperature to a lower setting.

cooling coil behind decorative

 

Air directional louvers positioned improperly. Position louvers for better air distribution.

front.

 

 

 

 

 

 

 

Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in

 

 

 

front of unit.

 

 

 

 

 

 

 

Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.

 

 

 

 

 

 

 

Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling,

 

 

 

floor and furniture.

 

 

 

Air conditioner turns on and off

Dirty air filter - air restricted. Clean air filter.

rapidly.

 

 

 

Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils

 

 

 

 

 

 

more frequently.

 

 

Noise when unit is cooling.

Air movement sound. This is normal. If too loud, set to lower FAN setting.

 

 

 

Window vibration - poor installation. Refer to installation instructions or check with installer.

 

 

Water dripping INSIDE when

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to

unit is cooling.

installation instructions or check with installer.

 

 

Water dripping OUTSIDE when

Unit removing large quantity of moisture from humid room. This is normal during excessively humid

unit is cooling.

days.

 

 

Remote Sensing Deactivating

Remote control not located within range. Place remote control within 20 feet & 120° radius of the

Prematurely (some models).

front of the unit

 

 

 

Remote control signal obstructed. Remove obstruction.

 

 

Room too cold.

Set temperature too low. lncrease set temperature.

 

 

 

 

 

 

 

Remote Sensing activated (on some models) and remote control located in Hot Spot - Relocate remote

 

 

 

control or deactivate remote sensing.

If These Solutions Fail, Call 1-800-944-9044 For Frigidaire Service.

12

2009 Electrolux Home Products, Inc.

All rights reserved.

 

 

 

 

Image 12
Contents Use&Care Important Safety Instructions Grounding type wall receptacleUnit must be upright for one hour prior to operating Product Registration, Packaging & Normal Sounds Product Registration Record Your Model and Serial NumbersAir Conditioner Features & Operating Instructions Electronic ControlTo Turn Unit on YOU will see To Adjust FAN Speeds To USE Auto FAN FeatureOperating Instructions To USE the Energy Saver Econ Feature YOU will see Sleep Feature YOU will seeTo Operate on FAN only YOU will see Timer Delay Stop / Start Feature Check Filter FEATURE, YOU will seeTo Change Temperature Display YOU will see Remote Sensing Feature on some models:Additional Things YOU should Know Fresh Air Vent Control on some modelsCare and Cleaning Occurrence Solution Before You CallMajor Appliance Limited Warranty Exclusions This warranty does not cover the following

FRA065AT7, FRA106CV1 specifications

Frigidaire is a well-known brand in the home appliance sector, renowned for its innovative cooling solutions. The Frigidaire FRA106CV1 and FRA065AT7 are two prominent air conditioning models that stand out due to their efficiency and user-friendly features.

The Frigidaire FRA106CV1 is a 10,000 BTU window-mounted air conditioner, specifically designed for cooling rooms up to 450 square feet. This model is particularly praised for its high-energy efficiency, achieving an Energy Efficiency Ratio (EER) of 12.1, which means it uses less energy to deliver powerful cooling. One of its standout features is the programmable timer, which allows users to set the unit to turn on or off at designated times, promoting energy savings. This model also features a quiet operation mode that ensures a peaceful environment, making it ideal for bedrooms or study spaces. The FRA106CV1 comes equipped with multiple cooling speeds and a fan-only mode, providing flexibility based on the user's comfort needs. Additionally, its washable filter is easy to access and clean, ensuring that air quality remains high while reducing maintenance costs.

On the other hand, the Frigidaire FRA065AT7 is a slightly smaller model, offering 6,000 BTUs of cooling power, making it suitable for spaces of up to 250 square feet. Like the FRA106CV1, this model is designed with energy efficiency in mind, featuring an EER of 12.2, which is excellent for a unit of its size. The FRA065AT7 includes mechanical controls, providing a straightforward interface for adjusting temperature and fan settings. Its ease of installation is another attractive aspect, as it comes with a convenient window mounting kit. The unit operates quietly, enhancing its suitability for small living areas, bedrooms, or home offices. It also has a washable filter that helps maintain air quality and reduces the frequency of filter replacements.

Both models are built with durable materials to withstand the test of time and provide reliable performance. With intuitive controls, energy-efficient operation, and reliable cooling power, the Frigidaire FRA106CV1 and FRA065AT7 air conditioners are excellent choices for homeowners seeking comfort and convenience in their living spaces. Each model offers unique features tailored to different room sizes, ensuring there is an option suitable for various cooling needs.