8-1. Cautions on troubleshooting

1.Before troubleshooting, check the following:

(1) Check the power supply voltage.

(2) Check the indoor/outdoor connecting wire for mis-wiring.

2.Take care of the following during servicing

(1)Before servicing the air conditioner, be sure to first turn off the remote controller to stop the main unit, and then after confirming the horizontal vane is closed, turn off the breaker and / or disconnect the power plug.

(2)Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic control P.C. board.

(3)When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the components.

(4)When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.

Lead wiring

Housing point

3. Troubleshooting procedure

 

(1)First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality. To make sure, check how many times the abnormality indication is flashing on and off before starting service work.

(2)Before servicing, check that the connector and terminal are connected properly.

(3)When the electronic control P.C. board seems to be defective, check the copper foil pattern for disconnection and the components for bursting and discolouration.

(4)When troubleshooting, refer to 8-2. and 8-3.

4. How to replace batteries

Weak batteries may cause the remote controller malfunction.

In this case, replace the batteries to operate the remote controller normally.

1 Remove the front lid and insert batteries.

2 Press the RESET button with tip end of ball point

Then reattach the front lid.

pen or the like, and then use the remote controller.

Insert the negative pole of the batteries first. Check if the polarity of the batteries is correct.

RESET button

NOTE : If the RESET button is not pressed, the remote controller may not operate correctly.

10

Image 10
Contents Contents Revised EDITION-BPart Names and Functions AccessoriesTechnical Changes Indoor Unit MSH-A18ND MSH-A24NDRemote Controller MSH-A18ND MSH-A24ND Specification MSH-A18ND MSH-A24NDOutlines and Dimensions MSH-A18ND MSH-A24ND Indoor UnitMSH-A18ND Indoor Unit Wiring DiagramMSH-A24ND Indoor Unit Refrigerant System Diagram Service Functions MSH-A18ND MSH-A24NDHow to release Auto Restart Function Troubleshooting Take care of the following during servicingInstruction of troubleshooting Troubleshooting check table Trouble criterion of main parts Check of indoor fan motor Check of indoor electronic control P.C. board How to check mis-wiring Indoor electronic control P.C. board Disassembly Instructions MSH-A18ND MSH-A24ND Indoor Unit Operating Procedure PhotosOperating Procedure Photos Parts List non-RoHS compliant Accessory and Remote Controller AIR Cleaning Filter RoHS Parts List RoHS compliant Vane Motor Vertical AIR Cleaning Filter Page Page Made in Japan