| OPERATING PROCEDURE |
| PHOTOS |
3. Removing the electrical box | Photo 3 | Screws of the ground wire | |
(1) | Remove the front panel. (Refer to 1.) |
| |
|
| ||
(2) | Remove the electrical cover. (Refer to 2.) |
|
|
(3) Disconnect the connector of the indoor coil thermistor.
(4)Disconnect the motor connector (CN211 and CN121) and the vane motor connector (CN151) on the electronic
| control P.C. board. | Screw of the | |
(5) | Remove the screws of ground wire. | electrical cover | |
(6) | Remove the fan motor lead wire and indoor coil thermistor |
|
|
|
| ||
Screw of the |
| ||
| from the electrical box. |
| |
| electrical box |
| |
(7) | Remove the lead wire of vane motor from the bottom of |
| |
|
| ||
|
| ||
| electrical box. |
|
|
(8)Remove the screw fixing the electrical box and remove the electrical box.
4. Removing the vane motor | Photo 4 |
| ||||
(1) | Remove the front panel. (Refer to 1.) | Vane motors | Screws | |||
(2) | Remove the electrical cover. (Refer to 2.) | |||||
| of the | |||||
(3) | Remove the lead wire of vane motor. (Refer to 3.) |
| ||||
| vane | |||||
(4) | Remove the R.L. holder. |
| ||||
| motor | |||||
(5) | Pull out the drain hose from the nozzle assembly and |
| ||||
|
| |||||
| remove the nozzle assembly. |
|
| |||
(6) | Remove the screws of the vane motor and disconnect the |
|
| |||
| connector. |
|
| |||
(7) | Remove the vane motor. |
|
| |||
Photo 5 Screws of the |
|
| ||||
|
| vane motor |
|
| ||
|
|
|
|
|
| |
|
| Vane motor |
|
|
5. Removing the line flow fan and the indoor fan motor | Photo 6 |
|
(1)Remove the front panel. (Refer to 1.)
(2)Remove the electrical box. (Refer to 3.)
(3)Pull out the drain hose from the nozzle assembly and
| remove the nozzle assembly. | Screws fixing | |
(4) | Remove the water cut. | ||
the left side | |||
(5) | Slide the hole cover and remove the hole cover. | ||
of the heat | |||
(6) | Remove the hexagon socket set screw from the line flow | ||
exchanger | |||
| fan. | ||
|
|
(7)Remove the screws fixing the fan motor and remove the fan motor. (Be careful not to drop the fan motor because it
is heavy.) | Photo 7 | |||
(8) Remove the screws fixing the left side of the heat |
| |||
exchanger. | Indoor | |||
(9) Lift the left side of the heat exchanger. | ||||
coil | ||||
(10) Remove the line flow fan. | ||||
thermistor | ||||
|
|
| ||
Photo 8 | Water cut | |||
|
|
| ||
|
|
|
| |
| Hole |
| ||
| cover |
|
| |
|
|
|
|
Screws fixing the fan motor
19