Mitsubishi Electronics MSZ12UN INSTALLATION, Relocation a, Installation place, Electrical work

Page 27

INSTALLATION, RELOCATION A

Installation place

Avoid installing the air conditioner in the following places.

Where flammable gas could leak.

CAUTION

Do not install the unit where flammable gas could leak.

If gas leaks and collects around the unit, it may cause an explosion.

Where there is much machine oil.

Salty places such as the seaside.

Where sulfide gas is generated such as a hot spring.

Where oil is splashed or where the area is filled with oily smoke.

 

 

Keep the outdoor unit 9.8 ft. or

 

 

more away from the antennas

 

 

of TV sets or radios.

To prevent the effects

Inverter-type

 

fluorescent lamp

 

of a fluorescent lamp,

wall, etc.

 

keep as far apart as

 

 

 

possible.

 

 

 

 

Well-

 

Keep a space

ventilated

 

to prevent the

dry place

 

picture

 

 

distortion or

4 in. or

 

the noise.

more

 

 

20 in. or

3.3 ft.

TV

more

or more

 

 

 

9.8 ft.

 

Radio

or more

WARNING

If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not when repairs are carried out.

The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful sub- stances will be generated.

Electrical work

Provide an exclusive circuit for the power supply of the air conditioner.

Be sure to observe the breaker capacity.

Use the correct power (voltage and frequency) indicated on the unit to operate the air conditioner and use only fuses or breakers with specified capacity. Do not use pieces of wire instead of fuses.

WARNING

The customer should not install this unit.

If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking, etc.

The unit should be installed by licensed contractor according to local code requirements.

CAUTION

Ground the unit.

Do not connect the ground to a gas pipe, water pipe, lightning rod or the ground of a telephone. If the ground- ing is incorrect, it may cause an electric shock.

If the air conditioner is installed in a high humidity area or near a water source, a Ground Fault Interrupt (GFI) circuit breaker should be installed to protect against an electric shock.

14

Image 27
Contents Operating Instructions Contents Safety Precautions This could damage your health Customer should not install this unitDo not turn the breaker off/on during operation Repairs or relocation should not be done by the customerDo not use an insecticide or flammable spray Do not operate switches with wet handsDo not clean the air con- ditioner with water Ventilate well in using the unit with a stove, etcReplace the 2 batteries with new ones of same type Do not step or put any- thing on the indoor/out- door unitDo not install the unit where flammable gas could leak Consult your dealer for installation of the air conditionerGround the unit Name of Each Part Indoor unitOutdoor unit Remote controller Open the front lid Mode MINPreparation Before Opera Auto restart functionBreaker for the air conditioner Ation Press the Emergency OPERA- Tion switchTo stop operation Press the button Description of I FEEL... modeFEEL... Auto Operation To start operation Press the button.ON/OFFDescription of Auto Restart Function Details of display on the indoor unitDetails of the display on the indoor unit are explained on To select the COOL, DRY or Heat modeManual Operation COOL, D To stop operationRY, Heat Cool For effective coolingDRY The humidity at which people feel comfortable Recommended horizontal vane range Cooling operation, when the air conditioner is opAIR Flow Velocity and Dire To change the AIR Flow velocity, press the FAN buttonAuto air flow direction control operation Ction AdjustmentPress the Start button during operation How to set the on timerSet the time of the timer using the HR. and MIN. buttons To release the OFF timer Press Stop buttonTurn off the breaker When it is not going to be used for a long timeWhen the air conditioner is to be used again Clean the air filter and install it in the in- door unitClean the unit using a soft dry cloth MaintenanceBefore starting maintenance Cleaning the indoor unitCleaning the air filter about once every 2 weeks Cleaning the deodorizing filter about once every 2 weeksRemove the air filter Remove the deodorizing filter Gray sponge type Deodorizing filter replacement about once a yearAir cleaning filter replacement about once every 4 months Remove the air cleaning filter White bel- lows typeFollowing cases, stop operation and consult your dealer Check the followingQuestion Answer not a malfunction When YOU Think That TroubBLE has Occurred INSTALLATION, Relocation a Installation placeElectrical work Relocation Inspection and maintenanceND Inspection Operating sound considerationsPage Specifications are subject to change without notice

MSZ12UN, MSZ09UN specifications

Mitsubishi Electronics has established itself as a leader in innovative climate control technology, and the MSZ09UN and MSZ12UN air conditioning units exemplify the company's commitment to energy efficiency, advanced technology, and user comfort. Both models are part of the MULTI-ZONE series, designed for residential and commercial spaces seeking an optimal balance between performance and energy savings.

The MSZ09UN, with a cooling capacity of 9,000 BTU, and the MSZ12UN, with a cooling capacity of 12,000 BTU, are ideal for small to medium-sized rooms. Their sleek and modern design allows them to blend seamlessly into any interior, while their quiet operation ensures that occupants can enjoy a comfortable environment without disruptive noise.

One of the standout features of both models is Mitsubishi's advanced inverter technology. This technology allows the units to automatically adjust the compressor's speed to maintain the desired temperature more efficiently. As a result, both units operate with lower energy consumption, which is especially appealing to environmentally conscious consumers. The inverter system not only enhances energy efficiency but also provides faster cooling and heating, ensuring that the desired temperature is reached quickly.

Both the MSZ09UN and MSZ12UN come equipped with a high-efficiency filter that captures dust and allergens, contributing to improved indoor air quality. Some models also feature optional plasma air purification technology, which further enhances air cleanliness by effectively eliminating bacteria and virus particles.

In terms of user convenience, these models offer easy-to-use remote controls, allowing users to adjust settings from a distance. They also support various operational modes, including cooling, heating, dehumidification, and fan-only modes, making them versatile solutions for year-round climate control.

Another notable characteristic is their compatibility with Mitsubishi's Kumo Cloud technology, enabling users to control their units remotely via smartphone apps. This feature provides enhanced convenience, allowing users to monitor and adjust their home's climate from virtually anywhere.

Overall, the Mitsubishi MSZ09UN and MSZ12UN air conditioners represent a perfect blend of technology, efficiency, and user-friendly features, making them excellent choices for anyone seeking reliable climate control solutions for their living or working spaces.