Mitsubishi Electronics PLA-A-AA installation manual System control, Installing the grille

Page 15

8. System control

Refer to the outdoor unit installation manual.

9. Installing the grille

1

 

 

 

 

2

 

 

3

 

4

 

 

5

 

6

 

 

 

 

 

 

Fig. 9-1

 

+3/16

0

 

A

 

A=11/16

 

 

 

 

B

 

D

 

 

C

 

 

 

 

 

 

 

 

Fig. 9-2

 

A

B

 

 

 

1

 

 

E

 

1

 

 

 

C

 

 

 

2

 

 

 

 

 

 

 

D

 

 

 

Fig. 9-3

 

 

G

F

 

B

 

 

 

 

F

 

 

1

 

 

 

 

 

 

 

Fig. 9-4

 

 

4-directional

 

3-directional

 

One pattern:

 

4 patterns:

 

Factory setting

One air outlet fully closed

Blowout

 

 

 

 

direction

 

 

 

 

patterns

 

 

 

 

 

2-directional

 

 

 

6 patterns:

 

 

 

 

Two air outlet fully closed

 

 

Blowout

 

 

 

 

direction

 

 

 

 

patterns

 

 

 

 

 

 

 

25/32

A Main unit

 

 

A

to

B Screw with

 

 

19/32

 

 

 

captive washer

 

 

 

 

 

 

B

 

 

 

 

Fig. 9-5

 

9.1. Checking the contents (Fig. 9-1)

This kit contains this manual and the following parts.

 

Accessory name

Q’ty

Remark

1

Grille

1

950 950 (mm), 37 - 3/8 37 - 3/8 inch

2

Screw with captive washer

4

M5 0.8 25

3

Gauge

1

(Divided into four parts)

4

Fastener

2

 

5

Screw

4

4 8

6

Wired remote controller

1

for PLP-42AAMD

9.2. Preparing to attach the grille (Fig. 9-2)

With the gauge 3 supplied with this kit, adjust and check the positioning of the unit relative to the ceiling. If the unit is not properly positioned relative to the ceiling, it may allow air leaks or cause condensation to collect.

Make sure that the opening in the ceiling is within the following tolerances:

860 860 - 910 910 mm, 33 - 7/8 33 - 7/8 to 35 - 13/16 35 - 13/16 inch.

Make sure that step A is performed within 17-22 mm, 11/16-7/8 inch. Damage could result by failing to adhere to this range.

A Main unit B Ceiling

C Gauge 3 (inserted into the unit) D Ceiling opening dimensions

9.2.1. Removing the intake grille (Fig. 9-3)

Slide the levers in the direction indicated by the arrow 1 to open the intake grille.

Unlatch the hook that secures the grille.

*Do not unlatch the hook for the intake grille.

With the intake grille in the “open” position, remove the hinge of the intake grille from the grille as indicated by the arrow 2.

9.2.2. Removing the corner panel (Fig. 9-4)

Remove the screw from the corner of the corner panel. Slide the corner panel as indicated by the arrow 1 to remove the corner panel.

A Intake grille

E Hole for the grille’s hook

B Grille

F Corner panel

C Intake grille levers

G Screw

D Grille hook

 

9.3. Selection of the air outlets

For this grille the discharge direction is available in 11 patterns. Also, by setting the Remote controller to the appropriate settings, you can adjust the air-flow and speed. Select the required settings from the Table according to the location in which you want to install the unit.

1)Decide on the discharge direction pattern.

2)Be sure to set the remote contoller to the appropriate settings, according to the number of air outlets and the height of the ceiling on which the unit will be in- stalled.

Note:

For 3 and 2-directional, please use the air outlet shutter plate (option).

9.4. Installing the grille

9.4.1. Preparations (Fig. 9-5)

Install the two enclosed screws with washer 2 in the main unit (at the corner drain pipe area and at the opposite corner) as shown in the diagram.

15

Image 15
Contents Air-Conditioners Safety precautions ContentsRefrigerant and drainage piping locations of indoor unit Installation locationInstalling the indoor unit Check the indoor unit accessories FigUnit suspension procedures Fig Branch duct hole and fresh air intake hole Fig13/16 For devices that use R410A refrigerant Installing the refrigerant pipingPrecautions Connecting pipes FigDrainage piping work Fig Drainage piping workIndoor unit Fig For twin/triple combinationDo not allow slackening of the terminal screws Remove the two electrical wiring service panelsEntries given in the diagram Electrical workL2 G B Power supplies onlyFor cooling only models Dip switch SW5-2 and SW5-3 is effective onlyControl application For heat pump modelsRemote controller For wired remote controllerFor wireless remote controller Assigning a remote controller to each unit Fig Function settingsFunction setting on the unit Selecting the unit functions Function setting on the remote controllerBefore test run Using wired remote controller FigUsing wireless remote controller Fig Test runSelf-check Using SW4 in outdoor unitWired remote controller Fig Wireless remote controller FigCheck of drainage Fig System control Installing the grilleInstalling the wireless sensor Fig Locking the up/down airflow direction FigCheck ⋅ 8 as shown in the illustration Easy maintenance function This function only for A-controlInstalling the intake grille Fig Display example Comp discharge temperature 147 FBG79U795H01

PLA-A-AA specifications

The Mitsubishi Electronics PLA-A-AA series is a cutting-edge range of air conditioning units designed to provide efficient cooling and heating solutions for various applications, from residential to commercial environments. This series stands out due to its innovative technology and user-friendly features.

One of the main highlights of the PLA-A-AA series is its use of advanced inverter technology. This technology allows the units to dynamically adjust their power output based on the current temperature conditions, ensuring that the desired climate is maintained efficiently. By minimizing energy consumption during operation, these systems can lead to significant savings on utility bills.

Additionally, the PLA-A-AA series is equipped with a built-in AI-driven control system that enhances user experience. This smart feature learns the user’s preferences and adjusts the operation accordingly, optimizing comfort while ensuring energy efficiency. The integration of smart technology also allows for remote control capabilities through mobile applications, enabling users to adjust settings from anywhere.

A notable characteristic of the PLA-A-AA units is their quiet operation. Designed with noise-reduction technology, these units operate at low decibel levels, making them ideal for settings where noise can be a concern, such as bedrooms and offices. This attention to sound design ensures that users can enjoy a peaceful environment without disruption.

The PLA-A-AA series also emphasizes sustainability and environmental responsibility. With a focus on using eco-friendly refrigerants, these systems have minimal impact on the environment. Mitsubishi Electronics continues to prioritize green technologies, consistently striving to reduce their carbon footprint through innovative engineering and efficiency programs.

Moreover, the units in this series are known for their durability and reliability. Constructed with high-quality materials and designed to withstand various climatic conditions, the PLA-A-AA series promises long-lasting performance. Regular maintenance is also simplified due to easily accessible components, helping to prolong the life of the unit.

In conclusion, the Mitsubishi Electronics PLA-A-AA series exemplifies the perfect blend of advanced technology, energy efficiency, and user-friendly features. With its inverter technology, smart control options, quiet operation, and commitment to sustainability, this range is an ideal choice for anyone seeking a dependable air conditioning solution.