Mitsubishi Electronics MSZ-GA35VA, MSZ-GA25VA Wiring Diagram, Refrigerant System Diagram, Unit mm

Page 8

6

WIRING DIAGRAM

MSZ-GA22VA - E1 MSZ-GA25VA - E1 MSZ-GA35VA - E1

MODELS WIRING DIAGRAM

INDOOR UNIT

 

 

 

 

 

 

INDOOR ELECTRONIC

 

4

 

 

 

 

 

TB

 

 

 

CONTROL P.C. BOARD

CN

 

 

RT13

 

 

 

TAB3

F11

3

 

 

 

230V~

BLK

 

 

 

 

 

S1

 

 

 

112

2

 

 

RT12

 

 

S2

 

 

DB111

T111

 

1

 

 

TO OUTDOOR

 

BLU

 

 

 

 

 

 

2

 

CN

 

 

 

UNIT

12-24V

S3

RED

NR11

 

 

 

 

RT11

 

 

111

 

 

CONNECTING

1

 

 

RED

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

CN201

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

BLK

5

 

 

 

 

 

 

 

 

 

MF

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

YLW

 

 

 

LD104

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

BLU

 

 

 

CN

CN

 

 

LD

LD

 

6

 

 

GRN

 

 

 

 

 

 

 

 

CN211

 

 

 

151

1R1

 

 

101(A)

105(T)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

2

 

 

6

2

 

 

 

 

 

 

MV

INTERLOCK

 

POWER MONITOR

SW P.C.

 

 

 

 

 

 

SWITCH(FAN)

 

RECEIVER P.C.BOARD

BOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

SYMBOL

NAME

SYMBOL

NAME

DB111

DIODE STACK

RT11

ROOM TEMPERATURE THERMISTOR

F11

FUSE (T3.15AL250V)

RT12

INDOOR COIL THERMISTOR (MAIN)

MF

INDOOR FAN MOTOR

RT13

INDOOR COIL THERMISTOR (SUB)

MV

VANE MOTOR (HORIZONTAL)

T111

TRANSFORMER

NR11

VARISTOR

TB

TERMINAL BLOCK

NOTE:1. About the outdoor side electric wiring refer to the outdoor unit electric wiring diagram for servicing.

2.Use copper conductors only. (For field wiring)

3.Symbols below indicate.

/: Terminal block, : Connector

7

REFRIGERANT SYSTEM DIAGRAM

MSZ-GA22VA - E1 MSZ-GA25VA - E1 MSZ-GA35VA - E1

INDOOR UNIT

Indoor

Indoor coil

thermistor

heat

RT12(main)

exchanger

 

 

Indoor coil

 

thermistor

 

RT13(sub)

Room temperature

thermistor

RT11

 

Refrigerant flow in cooling Refrigerant flow in heating

8

Unit : mm

Refrigerant pipe 9.52 (with heat insulator)

Flared connection

Flared connection

Refrigerant pipe 6.35 (with heat insulator)

Image 8
Contents Contents MSZ-GA22VA MSZ-GA25VA MSZ-GA35VATechnical Changes Generalized stepping motorPart Names and Functions Indoor Unit MSZ-GA22VA E1 MSZ-GA25VA E1 MSZ-GA35VA E1Accessories Indoor Unit MSZ-GA22VA E1 MSZ-GA25VA E1 MSZ-GA35VA E1MSZ-GA22VA E1 MSZ-GA25VA E1 Specification Specifications and rating conditions of main electric parts When outdoor unit is MXZ type MSZ-GA22VA E1 MSZ-GA25VA E1 MSZ-GA35VA E1Noise Criteria Curves MSZ-GA22VA E1 MSZ-GA35VA E1 MSZ-GA25VA E1Outlines and Dimensions MSZ-GA22VA E1 MSZ-GA25VA E1 MSZ-GA35VA E1 Indoor UnitUnit mm Required space Indoor unitUnit mm Wiring DiagramRefrigerant System Diagram Service Functions How to modify the remote controller P.C. boardRemote controller model KM05B J1 J2Troubleshooting Before troubleshooting, check the followingLead wiring Housing point OperationInformation for Multi System AIR Conditioner Failure mode recall function OFFIndoor unit failure mode table Instruction of troubleshooting Start Indoor unit operates. Outdoor unit doesnt operateTroubleshooting check table Indicates abnormalitiesTrouble criterion of main parts MXZ type Right lamp flashTroubleshooting flow Check of indoor fan motorCheck of remote controller and receiver P.C. board Indoor electronic control P.C.Board How to check mis-wiring and serial signal error LEDCheck of installation of the horizontal vane Electromagnetic noise enters into TV sets or radios YesTest point diagram and voltage Power monitor receiver P.C. boardMSZ-GA22VA E1 MSZ-GA25VA E1 Indoor electronic control P.C. boardDisassembly Instructions Removing the panel PhotoOperating Procedure Photos Removing the electrical boxRemoving the horizontal vane motor unit Photo Removing the indoor fan motor and the line flow PhotoFan Motor bandParts List Accessory and Remote ControllerIndoor Unit Structural Parts Controller Indoor Unit Structural PartsIndoor Unit Electrical Parts and Functional Parts Indoor Unit Heat ExchangerNozzle Assembly Interlock SwitchfanSwitch Holder Bearing MountAIR Cleaning Filter ANTI-ALLERGY Enzyme Filter Optional PartsMSZ-GA25VA MSZ-GA35VAPage Specifications subject to change without notice