MAKE ELECTRICAL CONNECTIONS
WARNING: Electrical wiring must be done by a qualified person(s) in accor- dance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wir- ing.
1.Remove the wiring box cover. Remove a knockout from the wiring box.
2.Secure the conduit to the wiring box through a conduit connector.
3.Make electrical connections. Connect white to white, black to black and green to green.
4.Replace wiring box cover and screws. Make sure that wires are not pinched between cover and box.
WIRING BOX
COVER
FIG.13
INSTALL DECORATIVE FLUES
1.Carefully place the decorative flue on the hood. Fig. 14.
-On ducted installation in rooms with
-On
-On ducted and
ROOMS WITH 10-FOOT CEILINGS (DUCTED HOODS ONLY)
Rooms with
2.Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 15.
3.Secure the upper flue with (2) 3.9x9.5mm mounting screws. Fig. 15.