Electrolux FKCH17F7HW Operation of Electrical Control Components, Ambient Thermostat, Fan Relay

Page 11
Figure 3-4. Fan Relay Terminal Arrangement

Electronic Control

Operation of Electrical Control Components

Freezer and Refrigerator Modules

The modules, when selected by the rocker switch, control the temperature of the unit by an internal thermistor mounted on the circuit board. Each module has an individual service mode.

Each module has the following connections to the rear of the circuit board:

1= Neutral

 

2= Not Used

 

3= L1

 

4= Compressor

 

5= Defrost Thermostat

 

DPDT Rocker Switch

L1

The DPDT Switch is connected to the household power

DPDT

supply with L1 connecting to terminal 2, and the Neutral

line to terminal 5. (See Figure 3-3)

Switch

 

In refrigerator mode, The DPDT switch will have the a

Nuetral

closed condition between terminals 5&4, and 2&1.

In freezer mode, The DPDT switch will have the a

 

closed condition between terminals 5&6 and 2&3.

 

Ambient Thermostat

 

The ambient thermostat will close at 35°F (1.6°C) and

Figure 3-3. DPDT Switch Arrangement

will then supply power to terminal 6 of the fan relay.

 

(See Figure 3-4)

 

Fan Relay

 

 

 

The purpose of the fan relay is to direct power to the

1

2

auxiliary heater and fan motor when ambient temperatures

3

 

go below 35°F (1.6°C) and the DPDT switch has

 

refrigeration selected.

 

 

Use an ohmmeter to test the fan relay. The following

5

 

conditions should result with the fan relay in the OFF state:

6

Between terminals 7

& 8 should read 4.4k Ohms.

7

8

Between terminals 6

& 2 and 5 & 1 - closed condition.

Between terminals 4

& 6 and 3 & 5 - open condition.

 

 

When voltage is supplied to terminal 6 through the ambient thermistor, voltage will come out terminal 2 and connect with terminal 1.

Terminal 1 is connected to terminal 5 which feeds power to the evaporator fan motor.

The following conditions should result with the fan relay in the ON state:

Line voltage is supplied to terminals 7&8.

Between terminals 4 & 6 - closed condition.

Between terminals 6 & 2 - open condition ( cutting power to the auxiliary heater).

Between terminals 3 & 5 - closed condition (supplying line voltage to the fan).

Between terminals 5 & 1 - open condition

2-3

Image 11
Contents Convertible Refrigerator / Freezer Page Basic Information SectionElectronic Control Safe Servicing Practices Installation InformationProduct Features Crisper Adjustable ShelvingDoor Storage Crisper DrawersSerial Plate Care and CleaningCleaning The Inside Cleaning The OutsideElectronic Control Setting Selection Electronic Temperature ControlSwitching Between Refrigerator and Freezer Mode Fan Relay Operation of Electrical Control ComponentsFreezer and Refrigerator Modules Ambient ThermostatService Diagnostic Mode Stuck Key Error IndicationFail Safe Mode Exiting Fail Safe ModeElectronic Control Refrigeration System Definitions Safety WarningsRefrigerant Cycle Basic ComponentsLow/High Side Leak or Undercharge Testing for Refrigerant LeaksCompressor Replacement Do not exceed 150 Psig To Flush The SystemTo Use Refrigerant To Flush The System Do not exceed 300 PsigDo not use compressor if you do not hear this sound Installing a New CompressorCondenser Replacement Evaporator and Suction Line Replacement Filter-Drier InstallationEquipment Needed for Evacuation & Recharging Installing Evacuation and Recharging EquipmentCharging The System Evacuating SystemFinal Leak Test Miscibility of R-134a and Ester Oil Verify Refrigerant Type In The SystemDedicated Equipment 134a Refrigeration SystemsWater In The Refrigeration System Refrigerant Leaks Vacuum Pump Maintenance134a properties Leak DetectionHFC-134a, CFC-12 Pressure Temperature Chart Skin and Eye Contact Inhalation ToxicityCardiac Sensitization Spills or LeaksBulk Delivery and Storage Leak TestingRefrigerant Recovery Systems Combustibility of HFC-134aComponent Teardown Component Teardown Kickplate Removal Door Hinge and Door Assembly RemovalExterior Components Door Handle RemovalDoor Gasket and Inner Panel Removal Door Stop RemovalTwo Liter Door Bin Removal Gallon Door Bin RemovalCrisper Drawer Removal Door Switch RemovalGlass Shelf Assembly Removal Interior ComponentsLight Fixture Removal Crisper Cover Assembly RemovalLight Shield Removal Evaporator Cover Removal Control Switch RemovalBaffle Plate Removal Electronic Control Removal 19. Evaporator Fan Assembly RemovalEvaporator Removal Defrost Thermostat RemovalDefrost Heater Removal Filter-Drier Removal Power Cord RemovalCompressor Area Components 25. Compressor Electrical Component Removal Compressor Removal27. Drain Pan Heater Loop Removal Drain Pan and Drain Pan Heater Loop RemovalCondenser Service Troubleshooting Problem Cause Correction Troubleshooting Compressor and evapora- tor fan motor does not run Troubleshooting Troubleshooting Wiring Diagrams Wiring Diagrams Wiring Diagrams Installation Information Safety Precautions Important Safety InstructionsInstallation Information To Level Unit LocationLeveling Electrical Receptacle Electrical InformationDoor Handle Mounting Instructions Door RemovalModel FKCH17F7HW Unit Dimensions Installation Information

FKCH17F7HW specifications

The Electrolux FKCH17F7HW is a standout refrigerator designed to meet the needs of modern households. With its sleek design and advanced features, it not only enhances the kitchen aesthetic but also promotes efficient food storage and preservation.

One of the key features of the FKCH17F7HW is its spacious interior. The refrigerator offers a generous capacity, making it ideal for families or individuals who like to stock up on groceries. Its flexible shelving system allows users to adjust the heights of shelves, accommodating very tall items and optimizing storage space.

The FKCH17F7HW comes equipped with advanced cooling technologies that ensure consistent temperature control. The Frost Free technology prevents the buildup of ice, saving users from the hassle of manual defrosting. This feature also allows for more efficient cooling, which in turn reduces energy consumption. The dynamic cooling system circulates air evenly throughout the refrigerator, helping to maintain an ideal temperature for perishable foods.

Another noteworthy characteristic is the humidity-controlled crisper drawers. These drawers provide an optimal environment for fruits and vegetables, keeping them fresher for longer. By regulating humidity levels, the crisper drawers also help to prevent spoilage, which not only saves money but contributes to less food waste.

In addition to storage practicality, the FKCH17F7HW incorporates energy-efficient technologies. The appliance is designed with an A+ energy rating, which means it operates with lower energy consumption without sacrificing performance. This eco-friendly feature not only benefits the environment but also reduces electricity bills.

The refrigerator also boasts user-friendly controls. Its intuitive electronic control panel makes it easy to adjust settings and ensure optimal performance. Moreover, the LED lighting illuminates the interior, making it easy to find what you need, even in low light conditions.

In summary, the Electrolux FKCH17F7HW is a remarkable refrigerator that combines style, functionality, and energy efficiency. With its generous capacity, advanced cooling technologies, and user-friendly features, it stands as a reliable appliance for any kitchen. Whether you're looking to preserve fresh produce or store family meals, this refrigerator meets a wide range of storage needs while maintaining an attractive design.