Electrolux FKCH17F7HW Combustibility of HFC-134a, Leak Testing, Bulk Delivery and Storage

Page 32

Refrigeration System

Combustibility of HFC-134a

HFC-134a is nonflammable at ambient

temperatures and atmospheric pressure. However, tests have shown HFC-134a to be combustible at pressures as low as 5.5 psig (139.3 kPa absolute) at 177°C (350°F) when mixed with air at concentrations generally greater than 60% volume air. At lower temperatures, higher pressures are required for combustibility. (HCFC-22 is also combustible at pressures above atmospheric in the presence of high air concentrations). Test results and calculations have shown:

At ambient temperature, all concentrations of HFC-134a in air are nonflammable at pressures below 15 psig (205 kPa absolute).

Combustible mixtures of air and HFC-134a will not form when liquid HFC-134a is pumped into closed vessel if initial air pressure in vessel is limited to one atmosphere absolute and final pressure is limited to 300 psig (2,170 kPa absolute). If initial air pressure is greater than one atmosphere, combustible mixtures may form as tank is filled.

Based on above information, the following operating practices are recommended:

Leak Testing

Equipment should NEVER be leak tested with a pressurized mixture of HFC-134a and air. HFC-134a may be safely pressured with dry nitrogen.

Bulk Delivery and Storage

Tanks should normally be evacuated at start of filling, and should never be filled while under positive air pressure.

Tank pressure should never be allowed to exceed 300 psig (2,170 kPa) when filling with HFC-134a. Relief devices on either tanks or HFC-134a supply system usually prevent this.

Tank pressures should be monitored routinely.

Air lines should never be connected to storage tanks.

Filling and Charging Operations

Before evacuating cylinders or refrigeration equipment, any remaining refrigerant should be removed by recovery system.

Vacuum pump discharge lines should be free of restrictions that could increase discharge pressures above 15 psig (205 kPa) and result in formation of combustible mixtures.

Cylinders or refrigeration equipment should normally be evacuated at start of filling, and should never be filled while under positive air pressure.

Final pressures should not exceed 300 psig (2,170 kPa).

Filled cylinders should periodically be analyzed for air (nonabsorbable gas or NAG).

Refrigerant Recovery Systems

Efficient recovery of refrigerant from equipment or containers requires evacuation at the end of the recovery cycle. Suction lines to a recovery compressor should be periodically checked for leaks to prevent compressing air into the recovery cylinder during evacuation. In addition, the recovery cylinder pressure should be monitored, and evacuation stopped in the event of a rapid pressure rise indicating the presence of noncondensable air. The recovery cylinder contents should then be analyzed for NAG, and the recovery system leak checked if air is present. DO NOT continue to evacuate a refrigeration system that has a major leak.

Thermal Decomposition

HFC-134a vapors will decompose when exposed to high temperatures from flames or electric resistance heaters. Decomposition may produce toxic and irritating compounds, such as hydrogen fluoride. The pungent odors released will irritate the nose and throat and generally force people to evacuate the area. Therefore, it is important to prevent decomposition by avoiding exposure to high temperatures.

3-18

Image 32
Contents Convertible Refrigerator / Freezer Page Section Basic InformationElectronic Control Installation Information Safe Servicing PracticesProduct Features Adjustable Shelving Door StorageCrisper Drawers CrisperCare and Cleaning Cleaning The InsideCleaning The Outside Serial PlateElectronic Control Setting Selection Electronic Temperature ControlSwitching Between Refrigerator and Freezer Mode Operation of Electrical Control Components Freezer and Refrigerator ModulesAmbient Thermostat Fan RelayService Diagnostic Mode Error Indication Fail Safe ModeExiting Fail Safe Mode Stuck KeyElectronic Control Refrigeration System Safety Warnings DefinitionsBasic Components Refrigerant CycleLow/High Side Leak or Undercharge Testing for Refrigerant LeaksCompressor Replacement To Flush The System To Use Refrigerant To Flush The SystemDo not exceed 300 Psig Do not exceed 150 PsigInstalling a New Compressor Do not use compressor if you do not hear this soundCondenser Replacement Filter-Drier Installation Evaporator and Suction Line ReplacementInstalling Evacuation and Recharging Equipment Equipment Needed for Evacuation & RechargingEvacuating System Charging The SystemFinal Leak Test Verify Refrigerant Type In The System Dedicated Equipment134a Refrigeration Systems Miscibility of R-134a and Ester OilWater In The Refrigeration System Vacuum Pump Maintenance Refrigerant LeaksLeak Detection 134a propertiesHFC-134a, CFC-12 Pressure Temperature Chart Inhalation Toxicity Cardiac SensitizationSpills or Leaks Skin and Eye ContactLeak Testing Refrigerant Recovery SystemsCombustibility of HFC-134a Bulk Delivery and StorageComponent Teardown Component Teardown Door Hinge and Door Assembly Removal Exterior ComponentsDoor Handle Removal Kickplate RemovalDoor Stop Removal Door Gasket and Inner Panel RemovalGallon Door Bin Removal Two Liter Door Bin RemovalDoor Switch Removal Glass Shelf Assembly RemovalInterior Components Crisper Drawer RemovalLight Fixture Removal Crisper Cover Assembly RemovalLight Shield Removal Evaporator Cover Removal Control Switch RemovalBaffle Plate Removal 19. Evaporator Fan Assembly Removal Electronic Control RemovalEvaporator Removal Defrost Thermostat RemovalDefrost Heater Removal Filter-Drier Removal Power Cord RemovalCompressor Area Components Compressor Removal 25. Compressor Electrical Component RemovalDrain Pan and Drain Pan Heater Loop Removal 27. Drain Pan Heater Loop RemovalCondenser Service Troubleshooting Problem Cause Correction Troubleshooting Compressor and evapora- tor fan motor does not run Troubleshooting Troubleshooting Wiring Diagrams Wiring Diagrams Wiring Diagrams Installation Information Important Safety Instructions Safety PrecautionsInstallation Information To Level Unit LocationLeveling Electrical Information Electrical ReceptacleDoor Removal Door Handle Mounting InstructionsModel FKCH17F7HW Unit Dimensions Installation Information

FKCH17F7HW specifications

The Electrolux FKCH17F7HW is a standout refrigerator designed to meet the needs of modern households. With its sleek design and advanced features, it not only enhances the kitchen aesthetic but also promotes efficient food storage and preservation.

One of the key features of the FKCH17F7HW is its spacious interior. The refrigerator offers a generous capacity, making it ideal for families or individuals who like to stock up on groceries. Its flexible shelving system allows users to adjust the heights of shelves, accommodating very tall items and optimizing storage space.

The FKCH17F7HW comes equipped with advanced cooling technologies that ensure consistent temperature control. The Frost Free technology prevents the buildup of ice, saving users from the hassle of manual defrosting. This feature also allows for more efficient cooling, which in turn reduces energy consumption. The dynamic cooling system circulates air evenly throughout the refrigerator, helping to maintain an ideal temperature for perishable foods.

Another noteworthy characteristic is the humidity-controlled crisper drawers. These drawers provide an optimal environment for fruits and vegetables, keeping them fresher for longer. By regulating humidity levels, the crisper drawers also help to prevent spoilage, which not only saves money but contributes to less food waste.

In addition to storage practicality, the FKCH17F7HW incorporates energy-efficient technologies. The appliance is designed with an A+ energy rating, which means it operates with lower energy consumption without sacrificing performance. This eco-friendly feature not only benefits the environment but also reduces electricity bills.

The refrigerator also boasts user-friendly controls. Its intuitive electronic control panel makes it easy to adjust settings and ensure optimal performance. Moreover, the LED lighting illuminates the interior, making it easy to find what you need, even in low light conditions.

In summary, the Electrolux FKCH17F7HW is a remarkable refrigerator that combines style, functionality, and energy efficiency. With its generous capacity, advanced cooling technologies, and user-friendly features, it stands as a reliable appliance for any kitchen. Whether you're looking to preserve fresh produce or store family meals, this refrigerator meets a wide range of storage needs while maintaining an attractive design.