Electrolux EFT 625, EFT925 user manual Special accessories, Installation

Page 5

Special accessories

Active carbon filter

When the hood is used in recirculation mode an active carbon filter should be used.

Order by the retailer

PNC 942 120 180

Installation

Unpacking

Check that the cooker hood has no damages. Trans- portation damages should immediately be reported to the one responsible for the transport Damages, faults and eventually missing details should immedi- ately be reported to the seller.

Take care of the packing material so that small children cannot play with it.

Placement

The hood is to be mounted on the wall or under a wall cupboard.

When installed, the hood must be not less than 60 cm. above electric burners or 70 cm. above gas or mixed-fuel burners. (Fig. 4).

Electrical connection

The hood has a power cord with moulded plug with earth connection to be connected to a wall outlet of 230 V.

The power cord length is 1 m.

Mounting of hood on wall

lFix the drilling template to the wall (Fig. 5).

lMake 3 Ø 8 mm holes in the wall. 2 at points H, 1 as desired at points I.

lInsert the three Ø 8 mm expansion plugs into the wall.

lInsert 2 5x45 screws at points H but do not tighten them completely.

lOpen the grid.

lFit the hood into holes H, tighten the 2 screws.

lFrom inside the hood, insert the third 5x45 screw into hole I (Fig. 6).

Min

Min

70 cm

60 cm

 

Fig. 4

H

I

H

I

H I I H

Fig. 5

I

I

OPEN

CLOSED

CLOSED

OPEN

Fig. 6

5

Image 5
Contents EFT Contents At installation and service Safety instructionsCongratulations to your new Cooker Hood At use of cooker hoodDescription of the appliance Standard accessories includedFunction ExhaustingInstallation Special accessoriesExhausting mode Using the hoodRecirculation mode with carbon filter Mounting under cupboardMaintenance Before you make contact to service CleaningService and spare parts If the hood does not functionModel EFT Technical dataPage Page LI1PJA Ed /01