Mounting under cupboard
lMake the holes on the bottom of the cupboard, using the drilling template (Fig. 7).
lFrom inside the cupboard, insert the 4 supplied screws and tighten them in the appropriate holes on the appliance.
Exhausting mode
lConnect the air outlet to the smoke exhaust hose
lOpen the suction grid (Fig. 12).
lRemove the carbon filter: push the hooks C and pull the filter downwards (Fig. 9).
lCheck that the selection lever for evacuation/ recycle is in the position A - external evacua- tion. (Fig. 8).
lRefit the suction grid.
Recirculation mode (with carbon filter)
The air outlets D (Fig. 2) must be shut.
lOpen the suction grid (Fig. 12).
lCheck that the selection lever for evacuation/ recycle is in the position : F - recycle (Fig. 8)
lCheck if carbon filter is already mounted and if not, fit carbon filter first rearwards on the proper seats.
lThen fix frontwards the carbon filter using hooks C (Fig. 9)
Using the hood
1 2 4 3
1
2 3
4
Fig. 7
F | F |
A | A |
Fig. 8
C
C
Fig. 9
Speed regulation
The hood has a three speed motor regulated with a slide switch plus a position for intensive operation.
For the best performance, we recommend using the highest speed in particular cases of strong odour and vapour concentration.
We recommend starting up the hood a few minutes before cooking and keeping it running until all the odours have been eliminated.
0 I | 0 I 2 3 |
EFT 625 - 925
Fig. 10