Electrolux K 98800-4i manual Technical terminology, Refrigerant Circuit, Evaporator, Compressor

Page 23

Technical terminology

Refrigerant

Liquids that can be used to a generate a cooling effect are known as refrigerants. They have a relatively low boiling-point, indeed so low, that the warmth from the food stored in the fridge or freezer can cause the refrigerant to boil and vaporise.

Refrigerant Circuit

Closed circulation system that contains the refrigerant. The refriger- ant circuit comprises primarily of an evaporator, a compressor, a con- denser and pipe work.

Evaporator

The refrigerant is evaporated in the evaporator. Similar to all other liquids, refrigerant requires heat to evaporate. This heat is removed from the interior of the appliance, as a result the interior is cooled. The evaporator is therefore located inside the appliance or placed in foam immediately behind the inner wall and thus not visible.

Compressor

The compressor looks like a small drum. It is driven by a built-in electric motor and is mounted on the base of the appliance at the rear. The task of the compressor is to draw in vaporised refrigerant from the evaporator, to compress it, and to pass it on to the con- denser.

Condenser

The condenser normally has the form of a grid. The refrigerant com- pressed in the compressor is liquefied in the condenser. During this process, heat is released to the surrounding air at the surface of the condenser. The condenser is mounted on the base of the appliance.

23

Image 23
Contents Santo Dear customer Contents Refrigerant Important Safety InstructionsPrior to initial start-up Case of malfunction Safety of childrenDaily Operation Disposal of Old Appliances DisposalRemove Transport Packaging Appliance Packaging InformationInstallation Location InstallationIntegratable models i-appliances InstallationPower Supply Your Refrigerator Needs AirGreen and Yellow Earth BlueNeutral BrownLive Electrical ConnectionView of the Appliance Description of the ApplianceControl Panel Temperature Setting ButtonsPrior to Initial Start-Up Starting Up and Temperature RegulationTemperature Display Coolmatic Button Switching Off the ApplianceHoliday Setting Variable Inner Door Interior AccessoriesStorage Shelves/Glass Shelves Variable Storage Box Humidity ControlBottle Holder Correct StorageFridge Defrosts Automatically Cleaning and CareDefrosting Correcting Malfunctions Energy Saving TipsWhat to do if Symptom Possible Cause Remedy Changing the Light Bulb Humming Noises During OperationRegulations, Standards, Guidelines ClicksCompressor Technical terminologyRefrigerant Circuit EvaporatorAEG Hausgeräte GmbH Postfach 90327 Nürnberg Electrolux plc