T h a n k s t o t h e c o n d e n s i n g u n i t , t h e outgoing air from the machine will be c o o l e d d o w n t o ~ 2 5 ° C a n d h a v e a humidity of 75 - 80%, so no additional hood is needed over the machine.
| WTF2 | WTF2H Heavy duty | WTF3 | WTF3H Heavy duty | WTF4H Heavy duty |
|
|
|
|
|
|
Tanks | 2 | 2 | 3 | 3 | 4 |
|
|
|
|
|
|
Total water Consumption l/h | 420 | 420 | 450 | 450 | 550 |
|
|
|
|
|
|
Air emission m3/h | 500 | 500 | 800 | 800 | 800 |
Air temperature °C | 20 - 25 | 22 - 25 | 22 - 30 | 22 - 30 | 22 - 30 |
|
|
|
|
|
|
Air humidity % | 75 - 85 | 75 - 85 | 75 - 85 | 75 - 85 | 75 - 85 |
|
|
|
|
|
|
Air humidity without ESD % | 100 | 100 | 100 | 100 | 100 |
|
|
|
|
|
|
*Final Rinse consumption l/h | 320 | 320 | 350 | 350 | 450 |
|
|
|
|
|
|
Energy savings ESD twin rinse | 30 | 30 | 30 | 30 | 30 |
|
|
|
|
|
|
*maximum values when m/c working all the time |
|
|
|
|
|