Electro-Voice CPS2.9, CPS2.12, CPS2.4 owner manual Mains Operation & Resulting Temperature, CPS2.6

Page 31

CONTRACTOR PRECISION SERIES

5.1 Mains Operation & Resulting Temperature

CPS2.4

Umains in V

Imains in A

Pmains in W

Pout in W

Pd in W1

BTU/hr2

Idle

230

0.3

38

0

38

130

 

 

 

 

 

 

 

Max. Output Power @ 8 Ω3

230

4.9

800

540

260

887

Max. Output Power @ 4 Ω3

230

8.0

1450

900

550

1877

1/3 Max. Output Power @ 4 Ω3

230

5.1

900

300

600

2047

1/8 Max. Output Power @ 4 Ω3

230

3.4

550

112.5

437.5

1493

1/8 Max. Output Power @ 4 Ω4

230

3.0

470

112.5

357.5

1220

1/8 Max. Output Power @ 4 Ω4 5

253

3.2

560

135

425

1450

Normal Mode (-10 dB) @ 4 Ω3

230

3.0

450

80

370

1262

Rated Output Power (0 dB) @ 4 Ω3

230

7.6

1380

800

580

1979

Alert (Alarm) Mode (-3 dB) @ 4 Ω3

230

5.7

1000

400

600

2047

Max. Output Power @ 2 Ω3

230

12.1

2250

1300

950

3242

1/8 Max. Output Power @ 2 Ω3

230

5.2

900

162.5

737.5

2516

1/8 Max. Output Power @ 2 Ω4

230

4.8

750

162.5

587.5

2005

CPS2.6

Umains in V

Imains in A

Pmains in W

Pout in W

Pd in W1

BTU/hr2

Idle

230

0.4

46

0

46

157

 

 

 

 

 

 

 

Max. Output Power @ 8 Ω3

230

6.7

1110

760

350

1194

Max. Output Power @ 4 Ω3

230

10.8

1970

1200

770

2627

1/3 Max. Output Power @ 4 Ω3

230

6.9

1150

400

750

2559

1/8 Max. Output Power @ 4 Ω3

230

4.6

740

150

590

2013

1/8 Max. Output Power @ 4 Ω4

230

4.0

630

150

480

1638

1/8 Max. Output Power @ 4 Ω4 5

253

4.5

760

190

570

1945

Normal Mode (-10 dB) @ 4 Ω3

230

3.9

610

100

510

1740

Rated Output Power (0 dB) @ 4 Ω3

230

10.0

1800

1000

800

2730

Alert (Alarm) Mode (-3 dB) @ 4 Ω3

230

7.5

1320

500

820

2798

Max. Output Power @ 2 Ω3

230

16.6

3260

1800

1460

4982

1/8 Max. Output Power @ 2 Ω3

230

7.1

1160

225

935

3190

1/8 Max. Output Power @ 2 Ω4

230

6.2

1040

225

815

2781

Power consumption is direct proportional for other mains voltages. The following conversion factors are meant for easy conversion: 100V = 2.3; 120V = 1.9; 240V = 0.96

1)Pd = Power Dissipation

2)1 BTU = 1055.06 J = 1055.06 Ws

3)Sine Signal Modulation (1 kHz)

4)Pink Noise according to EN60065 / 7. Edition

5)10% Mains Over Voltage

Owner‘s Manual / Bedienungsanleitung 31

Image 31
Contents Page Page Contractor Precision Series Owner‘s Manual Important Safety InstructionsUnpacking and Inspection Scope of Delivery and WarrantyFeatures and Description WelcomeHF-Interference FCC Information USA Front View Controls, Indicators and ConnectionsRear View Mounting Mains SwitchMains Operation & Resulting Temperature Operating VoltageGroundlift Power on delayHigh Pass Filter HPF Dual Selecting the Mode Of Operation and Audio Output CabelingAudio Input Cabeling IRIS-Net Volume ControlIndications 30dB...LIMITFan Cooling Standby Mode Power RemoteRCM-810 System Description and FeaturesControls and Connections Can addresses Data rate of the can bus is preset to 10 kbit/sSystem Example Owner‘s Manual Maximally allowable current at the +5V output is 200 mAContractor Precision Series Bedienungsanleitung Hinweise zur Entsorgung/Wiederverwendung gemäß WeeeEigenschaften & Beschreibung WillkommenAuspacken und Inspektion Lieferumfang und GarantieFrontseite Bedienelemente, Anzeigen und AnschlüsseRückseite Kühlung BetriebsspannungNetzschalter EinbauEinschaltverzögerung Hochpassfilter HPFBetriebsart Mode und Verkabelung des Audio-Ausgangs Verkabelung des Audio-Eingangs Anzeigen Eingangspegel-ReglerLüfter Standby-Modus Power RemoteBedienelemente und Anschlüsse SystembeschreibungADDRESS-Wahlschalter Die Datenrate ist auf 10 kbit/s voreingestelltCangnd Der maximale Strom am Ausgang +5V beträgt 200 mACPS2.9 CPS2.12 CPS2.4Owner‘s Manual / Bedienungsanleitung CPS2.6 Mains Operation & Resulting TemperatureCPS2.9 Block Diagram / Blockschaltbild Dimensions / Abmessungen Page Americas EUROPE, Africa & MIDDLE-EAST Asia & Pacific RIM