Electrolux U20412 manual Instructions for the Installer, Engineers technical data

Page 9

Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

Height:

8 mm.

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness:

30 mm.

SUPPLY CONNECTIONS

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Ignition HT Spark

 

 

Spark Generator

Ispra Control's BF 50066 - 230-240V

0.6 YA T 120

Spark Gap

Fixed

 

Rear Left Burner (semi-rapid)

Rear Right Burner (semi-rapid)

Heat Input 2.0 kW (6824 BTU/HR)

Heat Input 2.0 kW (6824 BTU/HR)

Front Left Burner (rapid)

Front Right Burner (auxiliary)

Heat Input 3.0 kW (10236 BTU/HR)

Heat Input 1.0 kW (3412 BTU/HR)

TYPE OF

 

 

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

GAS

Characteristics

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

NATURAL GAS

 

VALUE = 37.78 MJ/m Ws - 50.7 MJ/ m3

NOMINAL THERMAL

 

 

 

 

 

 

20 mbar

POWER

kW

3.0

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

m3/h

0.286

0.062

0.190

0.043

0.095

0.031

NOZZLE REFERENCE

119

Adjust.

9 6

Adjust.

7 0

Adjust.

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-30/37 mbar

VALUE = 49.92 MJ/Kg

NOMINAL THERMAL

 

 

 

 

 

 

LPG GAS

POWER

kW

2.8

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

g/h

202

4 7

144

3 2

7 2

2 4

NOZZLE REFERENCE

8 6

4 0

7 1

3 2

5 0

2 8

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

APPLIANCE CLASS: 3

APPLIANCE CATEGORY: II2H3+

APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar

9

Image 9
Contents Instruction Booklet Important Safety Information Description of the Hob ContentsOperation Maintenance and CleaningHob Top Pan SupportsSymptom Solution Service and Spare PartsSomething Not Working? ElectroluxElectrolux Standard Guarantee Conditions Guarantee ConditionsEuropean Guarantee ExclusionsScotland Channel IslandsNorthern Ireland WalesLondon & East Anglia MidlandsSouth East South WestEngineers technical data Instructions for the InstallerInstallation Important safety requirementsWhen the HOB is First Installed LocationGas Connection BuildingCut Out Size Building over a cupboard or drawerFitting the Hob into the worktop Electrical connectionsPermanent Connection This HOB Must be EarthedFault Finding Wiring DiagramPreliminary Electrical Systems CheckIgnition System / Gas Ignition To Adjust the GAS Rate CommissioningConversion from Natural Gas to Grafihe MDM Forlì