Emerson 5081-P-FF/FI instruction sheet Label, I.S. Fm, P-Fi, Uniloc

Page 17
Uniloc

This document contains information proprietary to

 

RELEASE DATE

ECO NO

REV

 

 

REVISIONS

 

 

 

Rosemount Analytical, and is not to be made available

 

 

 

 

 

 

 

 

 

 

to those who may compete with Rosemount Analytical.

Ø .125

5-6-04

8933

A

LTR

ECO

DESCRIPTION

BY

DATE

CHK

 

 

 

 

 

 

 

 

 

 

4X R .25

.120 ±.015

ROSEMOUNT R ANALYTICAL

B 9241503-

MODEL

FM

5081-P-FI-67

APPROVED

INTRINSICALLY SAFE FOR

CLASS I, II & III, DIV. 1,

GRPS. A,B,C,D,E,F & G

HAZARDOUS AREA WHEN

CONNECTED PER DWG. 1400287

T4 Tamb= 70°C

NON-INCENDIVE

CLASS I, DIV. 2, GRPS. A,B,C & D

DUST IGNITION PROOF

CLASS II AND III, DIV. 1,

GRPS. E, F & G

WARNING: COMPONENT SUBSTITUTION

MAY IMPAIR INTRINSIC SAFETY

OR SUITABILITY FOR DIV. 2.

NEMA 4X ENCLOSURE.

2X FULL R

EXPLOSION PROOF

CLASS I, DIV.1, GRPS. B,C & D

CLASS II, DIV. 1, GRPS. E,F & G

CLASS III, DIV. 1

PER DWG. 1400296

.1409241503-01/A

.125

2X.650 ±.015

1.30 ±.02

2.180

2.56 ±.02

THIS DOCUMENT IS

CERTIFIED BY

FM REV A

REV

REV

REV

REV

REV

REVISIONS NOT PERMITTED

W/O AGENCY APPROVAL

01

4FINISH:SILKSCREEN BLACK EPOXY PAINT (BAKED).

3.ARTWORK IS SHEET 2 OF 2.

UNLESS OTHERWISE SPECIFIED

.XX

+

TOLERANCES

 

 

.030

+

1/2

.XXX

-

ANGLES

+

.010

-

 

 

-

 

 

ITEM

PART NO

DESCRIPTION

QTY

BILL OF MATERIAL

2.NO CHANGE WITHOUT FM APPROVAL.

1MATERIAL: AISI 300 SERIES STAINLESS STEEL .015+/-.005 THICK. MATERIAL TO BE ANNEALED & PASSIVATED. MAXIMUM HARDNESS BRINELL 190.

NOTES: UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

REMOVE BURRS & SHARP EDGES .020 MAX MACHINED FILLET RADII .020 MAX

NOMINAL SURFACE FINISH 125

MATERIAL

1

FINISH

4

APPROVALS

DATE

DRAWN

B. JOHNSON

5/3/04

 

 

 

CHECKED

J. FLOCK

5/6/04

 

 

 

PROJECT

J. FLOCK

5/6/04

ENGR APVD

THIS DWG CREATED IN

SOLID EDGE

Uniloc

 

 

Irvine, CA 92606

 

 

 

 

 

Rosemount Analytical,

 

 

 

 

 

Uniloc Division

 

 

 

 

 

2400 Barranca Pkwy

 

TITLE

LABEL, I.S. FM

 

 

 

 

B

 

 

5081-P-FI

 

DWG NO

9241503-01

 

 

REV

SIZE

 

 

 

A

 

 

 

 

 

 

 

SCALE 2:1

 

 

SHEET 1 OF

2

17

Image 17
Contents Instruction Sheet ESSENTIAL INSTRUCTIONSREAD THIS PAGE BEFORE PROCEEDING FOUNDATION Fieldbus Two-WirepH/ORP TransmitterSPECIFICATIONS -GENERAL WIRING THROUGH A JUNCTION BOX SENSOR WIRING AND SET-UPPOWER WIRING FIGURE 1. Model 5081-P-FF/FIWiring DetailsWIRING 45081P30FIGURE 2. Exploded View of Model 5081-P-FF/FI MODEL 5081-P-FF/FI45081P29 45081P28INSTALLATION INSTALLATIONUNPACKING AND INSPECTION ROTATING THE DISPLAYPage HAZARDOUS AREA INSTALLATION FIGURE 7. FMRC Explosion-ProofInstallationHAZARDOUS AREA INSTALLATION MODEL 5081-P-FF/FIFIGURE 9. FM Intrinsically Safe Installation 1 of FIGURE 9. FM Intrinsically Safe Installation 2 of Page Page Page Page Page Page Uniloc LABEL, I.S. FM5081-P-FI SAFE AREA WIRING LABELSAFE AREA D1400296HAZARDOUS CLASSIFIEDLOCATIONS FISCONON-HAZARDOUSLOCATIONS 14002871400287 LABEL, I.S. CSA 9241504-01Uniloc 5081-P-FI1400288 FISCO CSA INTRINSIC SAFETY INSTALLATION1400288 HAZARDOUS AREA9241502-01 LABEL, I.S. BAS/ATEX5081-P-FI UnilocFISCO ATEX INTRINSIC SAFETY INSTALLATION1400293 1400293IRC - INFRARED REMOTE CONTROL INFRARED REMOTE CONTROLLER IRC - KEY FUNCTIONSInfrared Remote Controller MENU Sub-menu START-UPCONFIGURATION AND CALIBRATION - pHCALIBRATE PROGRAMFIGURE 15. Menu Tree for ORP START-UPCONFIGURATION AND CALIBRATION - ORP2511 mV MENUSpecifications subject to change without notice PROGRAM MENU MNEMONICSThe right people, the right answers, right now ON-LINEORDERING NOW AVAILABLE ON OUR WEB SITE