Nu-Vu PMA 5/18, PMA -5/12 Warranty Limitations, Change performed, Test time, Total time

Models: PMA -5/12 PMA 5/18

1 21
Download 21 pages 12.34 Kb
Page 6
Image 6
Change performed

NU–VU® EQUIPMENT WARRANTY

 

PMA–5/12 AND PMA–5/18 OWNER'S MANUAL

NU-VU®FOOD SERVICE SYSTEMS

 

STANDARD TIME ALLOWANCES FOR WARRANTY REPLACEMENTS

Change performed

Change time

Test time

Total time

Oven Motor/Rebalance Wheel

1 hr.

½ hr.

1½ hr.

Oven Heating Element

1 hr.

½ hr.

1½ hr.

Temperature Control

½ hr.

½ hr.

1 hr.

Temperature Sensor

½ hr.

½ hr.

1 hr.

Timers and/or Alarms

½ hr.

5 min.

½ hr.

Contactor/Relay

½ hr.

5 min.

½ hr.

Power Switch

¼ hr.

5 min.

¼ hr.

Indicator Light

¼ hr.

5 min.

¼ hr.

NU-VU®has determined that the listed times, which are based on the period necessary for a trained service person to perform the work noted, are fair and reasonable. If a problem is not diagnosed within a half hour, the service person must contact the NU-VU®Service Department via telephone at (906) 863-4401. Additional time for problem solving will not be allowed unless this procedure is followed. An appointment for servicing a unit should be set up since time will not be allowed for waiting to service a unit. Unless the service person justifies extra time for performing the work noted, charges for work performed by the service person in excess of the allowed time shall either be billed to the owner of the equipment or denied.

IMPORTANT: NU–VU®WILL NOT PAY FOR ANY SERVICE CALLS AS WARRANTY WORK IF A NU–VU®AUTHORIZED SERVICE AGENCY DETERMINES THAT YOUR UNIT IS SET UP AND OPERATING PROPERLY!

WARRANTY LIMITATIONS:

NU-VU®will pay for parts and labor under warranty if there is a defective component, but not for:

Normal operational wear and tear on the following parts -

Light bulbs and fuses

Door gaskets, handles and catches

Damage attributable to customer abuse, including -

Proofer water pan allowed to run dry and burn.

Proofer fan motor damaged from not following outlined Dry-Out Procedure.

Lack of regular cleaning or maintenance.

Power supply problems, including -

Insufficient or incorrect voltage.

Damage to electrical components caused by a power surge or spike.

Incorrect installation (i.e., equipment not supplied with separate neutral or ground as required, or incorrect location of high-voltage power leg for 240-volt 3-phase units).

Damage to electrical components resulting from use of an incorrect power supply cord or circuit breaker.

Operational problems resulting from customer’s failure to follow established procedures outlined in the Owner’s Manual.

A service call if nothing is found to be wrong (any returned parts work as per spec when tested).

NU–VU® FOOD SERVICE SYSTEMS

MENOMINEE, MICHIGAN 49858

page 4

SALES FAX (906) 863-5889 • SERVICE FAX (906) 863-6322

(906) 863-4401

Page 6
Image 6
Nu-Vu PMA 5/18, PMA -5/12 owner manual Warranty Limitations, Change performed, Test time, Total time