INSTALLATION:

PMA–5/12 AND PMA–5/18 OWNER'S MANUAL

RECEIPT AND INSTALLATION

INSTALLATION:

A.Check to determine that the power source is the same voltage and phase as that indicated on the label on the side of the unit.

B.Position the unit where it is to be operated and adjust the unit so that it stands level and solid. Remove the glass Light Globes from the rear wall of the Oven and install the included 40-watt Appliance Bulbs. Replace the glass Light Globes and close the Oven Door securely.

IMPORTANT: DO NOT CONNECT THIS UNIT IF YOUR POWER SOURCE

DOES NOT MATCH THE UNIT REQUIREMENTS!!!

C.Carefully set all Controls and Switches to the OFF position.

D.The installing technician or electrician should remove the Outside Top of the unit (this panel is only pressed onto the top of the unit and should lift off easily). Connect the unit to the available power supply either through an attached cord and receptacle or through direct wiring by following these steps:

1.Take note of the labeling on the Power Terminal Block (Line 1, Line 2, Line 3).

2.Carefully identify the power source leads and attach them to the appropriate terminal connections.

3.Properly ground the unit BEFORE USE by attaching a grounding wire to the Ground Lug or Clamp provided next to the Power Terminal Block.

4.Allow enough slack in the wiring to allow for equipment to be moved about during installation and any future servicing.

E.Check the voltage at the terminals on the Power Terminal Block with a voltmeter and compare the

values with the label listings on the side of the Oven. If the values match the unit is ready for its INITIAL START-UP. If the readings DO NOT coincide you must call the NU-VU®Service Department.

F.Carefully position the Outside Top on the unit but do not press it into place. Position the unit in its final operating location and refer to the INITIAL START-UP PROCEDURE.

IMPORTANT: FAULTY INSTALLATION, IMPROPER USE, OR ANY OTHER FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SEVERE EQUIPMENT DAMAGE OR PERSONAL INJURY, AND MAY ALSO VOID ALL OR PART OF YOUR NU-VU®EQUIPMENT WARRANTY!!!

NU–VU® FOOD SERVICE SYSTEMS

MENOMINEE, MICHIGAN 49858

(906) 863-4401

SALES FAX (906) 863-5889 • SERVICE FAX (906) 863-6322

page 7

Page 9
Image 9
Nu-Vu PMA -5/12, PMA 5/18 owner manual Installation, Does Not Match The Unit Requirements