TIMER INSTRUCTIONS:

OPERATING INSTRUCTIONS

PMA–5/12 AND PMA–5/18 OWNER'S MANUAL

TIMER INSTRUCTIONS:

A.The Power Switch must be in the ON position with the LEDs in the Timer Display Window showing 000.

B.Press either the UP or DOWN Time Set key to enter the desired time in minutes and seconds. The set time will appear in the Timer's Display Window.

C.Start the Timer by pressing the Start-Stop key once. The Timer will count down one second at a time, flashing the remaining time in the Display Window. Pressing the Start- Stop key a second time will halt the Timer; the remaining time will flash in the Display Window. Pressing the Start- Stop key again will restart the Timer.

D.When the set time expires the Display Window will flash

000 and the Timer Alarm will sound; the operator can silence the Alarm by pressing the Start-Stop key. After the Alarm is turned OFF the Timer will automatically reset itself to the last entered time. Pressing the Start-Stop key will restart the Timer.

OPERATIONAL NOTES:

The entered time changes by 1 second with each "click" of a Time Set key. Holding either key down changes the time by 1-secondincrements for the first 35 seconds of change, 10-secondincrements for the next 8 minutes of change, and 1-minuteincrements for the remainder of the change to a maximum set time of 99 minutes and 00 seconds (99:00 in the Display Window). Releasing the Time Set key restores the 1-second increment of change.

The time setting can only be edited when the Timer is not running.

A Timer can be reset at any time during the cooking cycle by holding the Start-Stop key for 5 seconds; Timer to its original set time. The set time can now be edited, or the Timer can be restarted to count down from this point.

This digital Timer contains a short-term memory chip to prevent the loss of a Timer setting because of an accidental shut-down of the unit. The Timer will recall the last entered setting when the unit is restarted.