INITIAL START–UP

PMA–5/12 AND PMA–5/18 OWNER'S MANUAL

INITIAL START-UP PROCEDURE

A.Make sure the INSTALLATION of the unit is complete and correct. Check the exterior of the unit. All cover panels must be in place (with the exception of the Outside Top), and the unit itself must be securely seated on a level surface.

B.Check the interior of the unit. All interior parts must be installed and securely fastened. Make sure the Door is fully closed and latched (the Oven Motor will not run if the main Door is not fully closed). YOU MUST REMOVE ALL PROTECTIVE TAPE PRIOR TO TURNING POWER

ON.

C.Engage the main power supply and set the Power Switch to the ON position. The interior lights should come on and the Oven Blower Wheel should begin to rotate in a counter-clockwise direction as viewed from the inside of the Oven.

NOTE: The Oven Motor will not run if the Oven Door is not fully closed!

D.Set the Temperature Control to 300°. The Temperature Control Indicator Light will illuminate and the Oven will begin to heat up.

E.Carefully remove the Outside Top and measure the amperage on the exposed power supply lines.

Compare these readings to the label on the side of your unit. If the readings and label differ by any great amount turn the unit OFF and call the NU-VU®Service Department immediately at (906) 863- 4401. Carefully reposition the Outside Top on the Oven and press it into place if the amp readings and label coincide. Be careful not to pull or pinch any wires while replacing the Outside Top.

F.Set each of the Timers in turn from 15 to 30 seconds and allow them to count down (refer to the TIMER INSTRUCTIONS in the OPERATING GUIDE). An electronic Alarm should sound at the end of each timed cycle. If a Timer or Alarm does not work please review the TIMER

INSTRUCTIONS or refer to the TROUBLE–SHOOTING GUIDE. If you still have a problem call NU-VU®at (906) 863-4401 and ask for our Service Department. Someone there will be glad to assist you in any way possible.

NOTE. Press the Start-Stop key on the Timer to silence the Alarm earlier.

G.Place an accurate and reliable oven thermometer in the center of the Oven and allow the Oven to heat to 300°. Compare the thermometer reading and the Temperature Control setting when the Temperature Control Indicator Light goes out. If they differ by less than 10° the Oven is ready for use. If there is a difference of 10° or more you may wish to adjust the Temperature Control.

Please call the NU-VU®Service Department at (906) 863-4401 before attempting to adjust the Temperature Control!!!

Your PMA-5/12 or PMA-5/18 should now be

ready for all standard operations!!!

NU–VU® FOOD SERVICE SYSTEMS

MENOMINEE, MICHIGAN 49858

page 8

SALES FAX (906) 863-5889 • SERVICE FAX (906) 863-6322

(906) 863-4401

Page 10
Image 10
Nu-Vu PMA 5/18, PMA -5/12 owner manual Initial START-UP Procedure

PMA -5/12, PMA 5/18 specifications

Nu-Vu PMA 5/18 and PMA 5/12 are advanced models of portable modular air handling systems designed to offer superior climate control solutions for diverse environments. These units are particularly well-suited for various applications, such as industrial, commercial, and institutional settings, where air quality and energy efficiency are paramount.

One of the key features of the Nu-Vu PMA series is their compact design combined with powerful performance. The PMA 5/18 and PMA 5/12 models are engineered to efficiently manage larger volumes of air while maintaining an excellent balance between space-saving convenience and robust functionality. Their modular design allows for easy integration into existing systems or new installations, making them highly adaptable to different setups.

In terms of technology, both models utilize cutting-edge heat recovery systems that enhance energy efficiency and reduce operational costs. By recovering waste heat from exhaust air, these units can precondition incoming fresh air, leading to significant energy savings and improved HVAC performance. This feature also contributes to maintaining optimal indoor air quality by effectively regulating temperature and humidity levels.

Another notable characteristic of the PMA series is their advanced filtration systems. Equipped with high-efficiency particulate air (HEPA) filters, they ensure that even the tiniest airborne particles are captured, making them ideal for environments that require strict air quality standards. This is critical in applications ranging from laboratories to healthcare facilities, where airborne contaminants can pose serious health risks.

Ease of maintenance is also a consideration in the design of the Nu-Vu PMA 5/18 and PMA 5/12 models. Their user-friendly layout allows for quick access to key components, reducing downtime during servicing. This ensures that the units can operate seamlessly for extended periods, making them reliable assets in maintaining a controlled environment.

The PMA models are also equipped with sophisticated control systems that allow for precise monitoring and adjustments of air flow and environmental conditions. This level of control not only enhances comfort but also facilitates compliance with industry regulations and standards.

In summary, the Nu-Vu PMA 5/18 and PMA 5/12 air handling systems represent the pinnacle of portable climate control technology. With their energy-efficient design, advanced filtration systems, and user-friendly features, they stand out as versatile solutions for various air quality and climate management challenges in today's diverse settings.