PMA–5/12 AND PMA–5/18 OWNER'S MANUAL

MAINTENANCE AND CLEANING GUIDE

 

 

 

D.Position the new Gasket over the slot, allowing the ends to extend past the end of the slot. Press the mounting flange down into the slot on the Door frame. Use a roller tool to force the mounting flange into the slot by working the tool back and forth along the Gasket. Make sure the Gasket mounting flange is completely fitted into the slot and that the Gasket is free to slide back and forth in the slot.

IMPORTANT: DO NOT STRETCH OR PULL ON THE GASKET DURING THE INSTALLATION PROCESS. THIS WILL LATER CAUSE THE TRIMMED CORNERS TO SEPARATE AND PULL APART!!!

E.Use a sharp knife or a single-edged razor blade to cut the ends of the Gasket at a 45° angle (you can use the mitered corner joint on the Door as an angle guide). Cut the Gasket about 1/4" longer than the required length and work the excess back into the slot. This extra Gasket will help to create a nice tight corner joint, and allows for any follow-up trimming that may be necessary.

F.Work your way around the entire Door (or the section of the Door having the Gasket replaced). Make sure the Gasket is just tight into the corners. A bulging joint or pucker along the Gasket indicates a Gasket section that is cut too long. Joints that pull apart indicate a Gasket section (or sections) that are cut too short.

IMPORTANT: MAKE SURE THAT THE GASKET AND DOOR FRAME ARE COMPLETELY CLEAN AND DRY BEFORE APPLYING ANY SEALANT!!!

G.Seal the corner joints after the entire Gasket is properly fitted. Pull the joints apart only enough to put sealant on all the cut edges only. Allow the Gasket joint to come together. Smooth out any excess sealant to form a smooth surface on the face of the Gasket. Add more sealant to any spots as necessary and smooth them down.

H.A quality sealant will be dry to the touch and tack-free in one to two hours after application. However, it will not be completely cured until six to eight hours later. We recommend that you wait until after your sealant is completely cured before using your oven.

WARNING: SOME SEALANTS GIVE OFF ACIDIC FUMES AS THEY CURE. THESE FUMES MAY CAUSE IRRITATION TO THE EYES AND/OR NASAL PASSAGES. USE CAUTION WHEN OPENING YOUR UNIT AFTER WAITING FOR ANY FRESH SEALANT TO SET UP AND CURE!!!

NU–VU® FOOD SERVICE SYSTEMS

MENOMINEE, MICHIGAN 49858

(906) 863-4401

SALES FAX (906) 863-5889 • SERVICE FAX (906) 863-6322

page 15

Page 17
Image 17
Nu-Vu PMA -5/12, PMA 5/18 owner manual Maintenance and Cleaning Guide

PMA -5/12, PMA 5/18 specifications

Nu-Vu PMA 5/18 and PMA 5/12 are advanced models of portable modular air handling systems designed to offer superior climate control solutions for diverse environments. These units are particularly well-suited for various applications, such as industrial, commercial, and institutional settings, where air quality and energy efficiency are paramount.

One of the key features of the Nu-Vu PMA series is their compact design combined with powerful performance. The PMA 5/18 and PMA 5/12 models are engineered to efficiently manage larger volumes of air while maintaining an excellent balance between space-saving convenience and robust functionality. Their modular design allows for easy integration into existing systems or new installations, making them highly adaptable to different setups.

In terms of technology, both models utilize cutting-edge heat recovery systems that enhance energy efficiency and reduce operational costs. By recovering waste heat from exhaust air, these units can precondition incoming fresh air, leading to significant energy savings and improved HVAC performance. This feature also contributes to maintaining optimal indoor air quality by effectively regulating temperature and humidity levels.

Another notable characteristic of the PMA series is their advanced filtration systems. Equipped with high-efficiency particulate air (HEPA) filters, they ensure that even the tiniest airborne particles are captured, making them ideal for environments that require strict air quality standards. This is critical in applications ranging from laboratories to healthcare facilities, where airborne contaminants can pose serious health risks.

Ease of maintenance is also a consideration in the design of the Nu-Vu PMA 5/18 and PMA 5/12 models. Their user-friendly layout allows for quick access to key components, reducing downtime during servicing. This ensures that the units can operate seamlessly for extended periods, making them reliable assets in maintaining a controlled environment.

The PMA models are also equipped with sophisticated control systems that allow for precise monitoring and adjustments of air flow and environmental conditions. This level of control not only enhances comfort but also facilitates compliance with industry regulations and standards.

In summary, the Nu-Vu PMA 5/18 and PMA 5/12 air handling systems represent the pinnacle of portable climate control technology. With their energy-efficient design, advanced filtration systems, and user-friendly features, they stand out as versatile solutions for various air quality and climate management challenges in today's diverse settings.