Electrolux 95752 G manual Instructions for the Installer, Engineers technical data

Page 11

Instructions for the Installer

Engineers technical data

Overall dimensions

Width:

740 mm.

Depth:

520 mm.

Cut out dimensions

Width:

560 mm.

Depth:

480 mm.

Burner

Dia. Tap By-pass

 

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

Supply Connections

Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Ignition HT Spark

Spark Generator: Ispra Control's BF 50066 - 230-240V 0.6 YA T120

Spark Gap : Fixed

Heat Input

Semi-rapid Burner 1.9 kW (6483 BTU/HR)

Rapid Burner

2.9 kW Natural Gas

 

(9895 BTU/HR)

 

 

2.7 kW L.P.G.

 

 

(9212 BTU/HR)

 

Auxiliary Burner

1.0 kW (3412 BTU/HR)

Appliance class

 

3

Appliance category

II2H3+

Gas supply

Natural gas G20 / 20mbar

 

BURNER

RAPID

SEMI-RAPID

AUXILIARY

TYPE OF GAS

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

POSITION

M A X

MIN

M A X

MIN

M A X

MIN

NATURAL GAS

NOMINAL THERMAL

 

 

 

 

 

 

POWER (kW)

2.9

0.65

1.9

0.45

1.0

0.33

20 mbar

NOMINAL FLOW

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

RATE (m3/h)

0.276

0.062

0.181

0.043

0.095

0.028

37.78 MJ/m3

Ws - 50.7 MJ/ m3

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

 

(1/100 mm)

 

 

 

 

 

 

LPG GAS

NOMINAL THERMAL

 

 

 

 

 

 

POWER (kW)

2.7

0.65

1.9

0.45

1.0

0.33

28-30/37 mbar

NOMINAL FLOW

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

RATE (g/h)

195

46.8

137

32.4

72

23.8

49.92 MJ/Kg

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

86

40

71

32

50

28

 

(1/100 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Image 11
Contents Instruction Booklet 95752 G Gas hobDuring Use Important Safety InformationInstallation Child SafetyEnvironmental Information ServiceContents Description of the Hob InstallationHob burners OperationBurners Maintenance and CleaningHob Top Pan SupportsSomething Not Working? Symptom SolutionCustomer Care Service and Spare PartsEuropean Guarantee Guarantee ConditionsEngineers technical data Instructions for the InstallerLocation Important safety requirementsGas Connection InstallationBuilding over a cupboard or drawer BuildingCut Out Size Building over a kitchen unit with door Fitting the hob to the worktop This HOB Must be Earthed Electrical connectionsPermanent Connection Wiring diagramReplacement of the cable Preliminary Electrical Systems Check Fault FindingEarth Continuity Check Ignitor does not spark Ignition System / Gas IgnitionCommissioning Pressure TestingMethod To adjust the gas rateFrom the Electrolux Group. The world’s No.1 choice