Electrolux 95752 G manual Ignition System / Gas Ignition, Ignitor does not spark

Page 21

Ignition System / Gas Ignition

Ignitor does not spark

NO

Check plug top fuse and replace if necessary

Check polarity and earth continuity of supply point

Check earth continuity of appliance

YES

Check gas supply at burner

Light burner manually

Check by pass simmer adjusted

Check position of the electrode

Check fitting of burners

Check continuity from 'N' on the mains connector block and "O" on the ignitor unit

Check continuity from 'L' on the mains connector block and the taps ignition switches

Check continuity from ignition switches connector to ignitor unit

Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit

Check for breaks in the insulation of the HT leads

Change the taps ignition switches

Change the ignitor unit

21

Image 21
Contents Instruction Booklet 95752 G Gas hobInstallation Important Safety InformationChild Safety During UseEnvironmental Information ServiceContents Description of the Hob InstallationHob burners OperationHob Top Maintenance and CleaningPan Supports BurnersSomething Not Working? Symptom SolutionCustomer Care Service and Spare PartsEuropean Guarantee Guarantee ConditionsEngineers technical data Instructions for the InstallerLocation Important safety requirementsGas Connection InstallationBuilding Cut Out SizeBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop This HOB Must be Earthed Electrical connectionsWiring diagram Replacement of the cablePermanent Connection Preliminary Electrical Systems Check Fault FindingEarth Continuity Check Ignitor does not spark Ignition System / Gas IgnitionCommissioning Pressure TestingMethod To adjust the gas rateFrom the Electrolux Group. The world’s No.1 choice