Installation
Technical Specifications
Model |
| ARCTIS 189 GT | ARCTIS 261 GT |
Volume (gross) | litres | 189 | 261 |
Volume (net) | litres | 184 | 255 |
Height without/with roller | cm | 87,6/88,3 | 87,6/88,3 |
Width | cm | 93,5 | 119 |
Depth | cm | 66,5 | 66,5 |
Weight | kg | 49 | 57 |
Energy consumpt./24h | kWh | 0,53 | 0,64 |
Freezing capacity | kg/24h | 23 | 27 |
hours | 43 | 47 | |
Rated power | W | 75 | 100 |
|
|
|
|
Installation Location
The appliance should be set up in a well ventilated, dry room on a firm and level surface.
Warning! The appliance may not be exposed to spray or water splashes. There is a danger of electrical shock!
Energy use is affected by the ambient temperature.
The appliance should therefore
not be exposed to direct sunlight;
not be installed next to radiators, cookers or other sources of heat;
only be installed at a location whose ambient temperature corresponds to the climate classification, for which the appliance is designed.
The climate classification is stipulated on the serial plate which can be found on the inner side of the lid. The following table shows which ambient temperature is correct for each climate classification:
Climate classification | for an ambient temperature of |
SN | +10 to +32 °C |
N | +16 to +32 °C |
ST | +18 to +38 °C |
T | +18 to +43 °C |
|
|
7