Fitting the plinth
Important!
For the efficient operation of the appliance, it is important that the original ventilation grid is used.
•For an opening height dimension A=820 mm and a plinth height dimension a=100 mm, the plinth may be fitted without adjustments. The same applies to an opening height dimension B=870 mm and a plinth height dimension b=150 mm.
•For plinth heights greater than a=100 mm, b=150 mm, a cut should be made in the plinth, 580 mm wide, in the centre of the appliance position, leaving a remaining height of a=100 mm, b=150 mm.
A = 820 B = 870 | 100 150 |
| a = b = |
| 580 |
25 | - |
25 | 80 |
|
• Attach plinth to the kitchen units.
Important!
The plinth must be positioned at a minimum distance of 25 mm from the door.
Please check whether, after installing your appliance and especially after reversing the door, the door seal seals right round. A badly fitting door seal may lead to heavy frosting and result in a higher power con- sumption (see also “What to do if ...”).
Power supply
A correctly installed, earthed socket is required for the electrical sup- ply. The supply must have a fuse rating of at least 10 Amps. If the socket is not accessible once the appliance is built in, the electrical installation must include suitable means of isolating the appliance from the mains (e.g. a fused spur).
☞Before initial
e.g.: AC 220 | ... 240 | V 50 Hz or |
220 | ... 240 | V ~50 Hz |
(i.e. 220 to 240 volts alternating current, 50 Hertz) The rating plate is inside the appliance on the left.
15