Viking CRVDD330R, CRVDD336R, CRVDD345R warranty Intended for Domestic Cooking only

Page 1

VIKING RANGE, LLC

Downdraft Ventilators

MODEL

RVDD330R / CRVDD330R RVDD336R / CRVDD336R RVDD345R / CRVDD345R

WIDTH

BLOWER (purchase separately)

30" w/ remote control

VIDV500 Interior or VEDV900 Exterior

36" w/ remote control

VIDV500 Interior or VEDV900 Exterior

45" w/ remote control

VIDV500 Interior, VEDV900 Exterior, or VEDV1200 Exterior

WARNING - To reduce the risk of burns or ignition of clothing by reaching across burners, the downdraft remote control MUST be mounted in the countertop - at least 4" from the burners. See "INSTALL COOKTOP" section on page 8.

READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY !

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip- ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori- ties.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO

PREVENT BURNS. If the flames do not go out immediately,

EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN - You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher, and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

aBased on “Kitchen Firesafety Tips” published by NFPA.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.To reduce the risk of fire, use only metal ductwork.

8.Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the cook top or range top should be 4 inches.

9.Loose-fitting or hanging clothing should never be worn when operating this appliance. They may be ignited by burners/ elements on cooktop.

10.Children should not be left alone or unattended in the area where this appliance is in use.

11.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b)Always turn hood ON when cooking at high heat or when cooking flaming foods.

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d)Use proper pan size. Always use cookware appropriate for the size of the surface element.

CAUTION !

1.For general ventilating use only. Do not use to exhaust hazard- ous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.Clean filters and grease-laden surfaces frequently.

4.Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician.

5.Please read specification label on product for further informa- tion and requirements.

INSTALLER:

Save this manual for Electrical Inspector and Homeowner to use.

HOMEOWNER:

Use and Care Information on Page 11.

Image 1
Contents Evacuate and Call the Fire Department Intended for Domestic Cooking onlyTo Reduce the Risk of a Range TOP Grease Fire Electrical Specifications Interior Blower Installation Exterior Blower InstallationPlanning Take MeasurementsSide View Downdraft With VIDV500 Interior Blower Plan the DuctworkSide View Downdraft With Round Elbow For connection To VEDV900 or VEDV1200Plan the Cabinet Cutouts Interior Blower Installation Plan the WiringPrepare the Downdraft Important Location of Electrical OutletCUT Countertop Opening Mount the Unit Install DuctworkBefore Cutting Hole Cabinet for Ductwork Install Cooktop Install Electrical WiringBy a qualified persons in accordance with all Applicable codes and standardsInstallation of Remote Control Switch Backside Remote Switch Template Operation Supply before cleaning and/or servicing unitUSE and Care UP / DOWN-----RaisesSpecifications subject to change without notice F20126 BUILT-IN Rear Downdraft WarrantyVIDV500 intérieur, VEDV900 extérieur, ou VEDV1200 extérieur Destiné À LA Cuisine Domestique Seulement AvertissementPrise DES Mesures PréparationTous les appareils SpécificationsPréparation DES Conduits Prise DES Mesures SuiteVUE DE Côté DE LA Hotte Avec Ventilateur Intérieur VIDV500 VUE DE Côté DE LASortie À Gauche Installation du ventilateur intérieurSortie À Droite DE Découper L’ARMOIRE Pour LESPréparation DE LA Hotte Préparation DU CâblageImportant Position DE LA Prise ÉLECTRIQUE  Découpage DU Comptoir Modèle DE Ventilateur Dimensions VIDV500Tous les modèles Tion Ronde DEInstallation DES Conduits Installation DE L’UNITÉAvant DE Découper L’AR Moire Pour LES Conduits Assurez-vous que les solives duCâblage Électrique Installation DE LASurface DE Cuisson Bord DU Comptoir Installation DE LA TélécommandeArrière DU Gabarit DE LA Télécommande Utilisation ET Entretien FonctionnementAvertissement Coupez toujours le courant Avant de nettoyer ou d’entretenir l’appareilGarantie DES Hottes Encastrées

RVDD336R, CRVDD330R, CRVDD336R, CRVDD345R, RVDD345R specifications

The Viking CRVDD336R, RVDD345R, RVDD336R, CRVDD330R, and RVDD330R represent a series of advanced HVAC units designed to provide efficient cooling and heating solutions for a variety of commercial and residential applications. These models stand out due to their innovative technologies, energy efficiency, and user-friendly features.

One of the principal characteristics of these units is their robust design, enabling them to withstand harsh environmental conditions while maintaining performance consistency. Each model features a high-performance compressor and a well-engineered fan system that promotes optimal airflow. This ensures that indoor spaces are kept at comfortable temperatures while minimizing energy consumption.

Energy efficiency is a key highlight of the Viking line. Many of these models come equipped with inverter technology, which adjusts the compressor speed based on the cooling or heating demand. This not only lowers energy consumption but also reduces wear and tear on components, extending the lifespan of the system.

Additionally, the Viking CRVDD and RVDD series incorporate advanced control systems that enhance user experience. These controls allow for precise temperature settings and programmable schedules, providing flexibility to adapt to varying occupancy patterns. Moreover, some units are compatible with smart home systems, enabling remote access and management through mobile applications.

In terms of installation, these models are designed for versatility. They can be installed in various configurations, including ducted and ductless options, making them suitable for different building layouts. Their compact size also means they can fit in tight spaces while still providing powerful heating and cooling capabilities.

Maintenance is made easy with these units. Users can perform regular checks and service with minimal hassle, thanks to accessible components designed for quick inspections and replacements. Many models feature self-diagnosis capabilities, alerting users to potential issues before they escalate, further minimizing downtime.

Overall, the Viking CRVDD336R, RVDD345R, RVDD336R, CRVDD330R, and RVDD330R units are engineered to meet the demanding needs of today’s users. Their combination of efficiency, flexibility, and advanced technology positions them as excellent choices for anyone looking to upgrade their HVAC systems. With a strong focus on performance and sustainability, these models are an investment in comfort and reliability for years to come.