Viking RVDD330R Planning, Interior Blower Installation Exterior Blower Installation, All Units

Page 2

VIKING RANGE, LLC

Downdraft Ventilators

 

 

PLANNING

Interior Blower Installation

Exterior Blower Installation

This downdraft blower system is

TYPICAL INSTALLATION

designed to be used to exhaust

COUNTER

CHIMNEY TOP

airborne contaminants when

 

 

cooking with a variety of gas

TOP

COOK TOP

 

 

 

 

 

 

 

or electric cooktops. It can be

 

 

 

 

 

mounted in island, peninsula,

 

 

 

AIR

or conventional wall locations.

 

 

GEAR

VENT

This unit can be easily installed

 

 

MOTOR

 

 

 

 

COVER

 

 

following these basic steps:

 

 

BLOWER

 

 

• Cut out the countertop

 

 

 

 

 

 

BOX

 

 

opening.

 

 

 

120 VAC

• Mount the unit in the cabi-

 

 

 

GROUNDED

 

 

 

OUTLET

net.

 

 

 

 

 

• Install the Model VIDV500

 

 

 

 

 

Interior Blower

 

 

 

3-1/4" X 10"

• Connect the ductwork and

 

 

 

 

 

 

DUCT CONNECTOR

electrical.

 

 

 

 

 

• Install the cooktop.

 

 

ELECTRICAL

 

 

 

SPECIFICATIONS

 

Note: the high level of air flow

 

 

 

 

120 VAC • 60 Hz • 4.0 A

 

of this appliance may effect the

 

 

gas flame on some types of gas

 

 

 

 

 

 

 

 

 

 

cooktops.This is NORMAL and

 

 

 

 

 

This downdraft blower system is designed to be used to ex- haust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, peninsula, or conventional wall locations.

This unit can be easily installed following these basic steps:

Cut out the countertop opening.

Mount the unit in the cabinet.

Install 10" round dis- charge plate

Install Model VEDV900 or VEDV1200 (DIPR151RSS only) External Blower

Connect the ductwork and electrical.

Install the cooktop.

TYPICAL INSTALLATION

COUNTER TOP

CHIMNEY TOP

COOK TOP

AIR

GEARMOTOR VENT

COVER

10" ROUND DISCHARGE PLATE

120 VAC GROUNDED OUTLET

10" ROUND DUCTWORK

ELECTRICAL

SPECIFICATIONS

120 VAC • 60 Hz • 6.0 A (max.)

will cause no harm, but can be

corrected by lowering the speed

of the blower.

Note: the high level of air flow of this appliance may effect the gas flame on some types of gas cooktops. This is NORMAL and will cause no harm, but can be corrected by lowering the speed of the blower.

TAKE MEASUREMENTS

All Units

1.Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. The Model RVDD330R / CRVDD330R will fit in most 30" wide cabinets, the Model RVDD336R / CRVDD336R will fit in most 36" wide cabinets, and the Model RVDD345R / CRVDD345R will fit most 45" wide cabinets. However, it is recommended that oversized cabinets be used for easier installation.

2.Cooktop depth can vary greatly from one to another.This may cause the fit of these two appliances to be rather tight.

Pay special attention to the areas of potential interference high- lighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2" of flat countertop is required behind cooktop and that 1-3/4" is necessary between the back edge of the cooktop and the inside of cabinet back.

2

Image 2
Contents To Reduce the Risk of a Range TOP Grease Fire Intended for Domestic Cooking onlyEvacuate and Call the Fire Department Planning Interior Blower Installation Exterior Blower InstallationElectrical Specifications Take MeasurementsSide View Downdraft With Round Elbow Plan the DuctworkSide View Downdraft With VIDV500 Interior Blower For connection To VEDV900 or VEDV1200Plan the Cabinet Cutouts Prepare the Downdraft Plan the WiringInterior Blower Installation Important Location of Electrical OutletCUT Countertop Opening Before Cutting Hole Cabinet for Ductwork Install DuctworkMount the Unit By a qualified persons in accordance with all Install Electrical WiringInstall Cooktop Applicable codes and standardsInstallation of Remote Control Switch Backside Remote Switch Template USE and Care Supply before cleaning and/or servicing unitOperation UP / DOWN-----RaisesBUILT-IN Rear Downdraft Warranty Specifications subject to change without notice F20126Destiné À LA Cuisine Domestique Seulement Avertissement VIDV500 intérieur, VEDV900 extérieur, ou VEDV1200 extérieurTous les appareils PréparationPrise DES Mesures SpécificationsVUE DE Côté DE LA Hotte Avec Ventilateur Intérieur VIDV500 Prise DES Mesures SuitePréparation DES Conduits VUE DE Côté DE LASortie À Droite Installation du ventilateur intérieurSortie À Gauche DE Découper L’ARMOIRE Pour LESImportant Position DE LA Prise ÉLECTRIQUE  Préparation DU CâblagePréparation DE LA Hotte Tous les modèles Modèle DE Ventilateur Dimensions VIDV500Découpage DU Comptoir Tion Ronde DEAvant DE Découper L’AR Moire Pour LES Conduits Installation DE L’UNITÉInstallation DES Conduits Assurez-vous que les solives duSurface DE Cuisson Installation DE LACâblage Électrique Installation DE LA Télécommande Bord DU ComptoirArrière DU Gabarit DE LA Télécommande Avertissement Coupez toujours le courant FonctionnementUtilisation ET Entretien Avant de nettoyer ou d’entretenir l’appareilGarantie DES Hottes Encastrées

RVDD336R, CRVDD330R, CRVDD336R, CRVDD345R, RVDD345R specifications

The Viking CRVDD336R, RVDD345R, RVDD336R, CRVDD330R, and RVDD330R represent a series of advanced HVAC units designed to provide efficient cooling and heating solutions for a variety of commercial and residential applications. These models stand out due to their innovative technologies, energy efficiency, and user-friendly features.

One of the principal characteristics of these units is their robust design, enabling them to withstand harsh environmental conditions while maintaining performance consistency. Each model features a high-performance compressor and a well-engineered fan system that promotes optimal airflow. This ensures that indoor spaces are kept at comfortable temperatures while minimizing energy consumption.

Energy efficiency is a key highlight of the Viking line. Many of these models come equipped with inverter technology, which adjusts the compressor speed based on the cooling or heating demand. This not only lowers energy consumption but also reduces wear and tear on components, extending the lifespan of the system.

Additionally, the Viking CRVDD and RVDD series incorporate advanced control systems that enhance user experience. These controls allow for precise temperature settings and programmable schedules, providing flexibility to adapt to varying occupancy patterns. Moreover, some units are compatible with smart home systems, enabling remote access and management through mobile applications.

In terms of installation, these models are designed for versatility. They can be installed in various configurations, including ducted and ductless options, making them suitable for different building layouts. Their compact size also means they can fit in tight spaces while still providing powerful heating and cooling capabilities.

Maintenance is made easy with these units. Users can perform regular checks and service with minimal hassle, thanks to accessible components designed for quick inspections and replacements. Many models feature self-diagnosis capabilities, alerting users to potential issues before they escalate, further minimizing downtime.

Overall, the Viking CRVDD336R, RVDD345R, RVDD336R, CRVDD330R, and RVDD330R units are engineered to meet the demanding needs of today’s users. Their combination of efficiency, flexibility, and advanced technology positions them as excellent choices for anyone looking to upgrade their HVAC systems. With a strong focus on performance and sustainability, these models are an investment in comfort and reliability for years to come.