Viking RVDD330R Install Electrical Wiring, Install Cooktop, Applicable codes and standards

Page 8

VIKING RANGE, LLC

Downdraft Ventilators

 

 

INSTALL ELECTRICAL WIRING

Interior Blower Installation

!

CAUTION: All electrical wiring should be done

by a qualified person(s) in accordance with all

applicable codes and standards.

1.Mount a standard wiring box, with 3-pronged receptacle, inside the cabinet. Make sure the downdraft's power cord can easily reach it.

2.Run appropriate power cable into cabinet and connect it to receptacle.

3.Plug the downdraft's power cord into the outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.

INSTALL COOKTOP

Exterior Blower Installation

!

CAUTION: All electrical wiring should be done

by a qualified person(s) in accordance with all

applicable codes and standards.

1.Mount a standard wiring box, with 3-pronged grounded recep- tacle, inside the kitchen cabinet. Make sure the downdraft's power cord can easily reach it.

2.Run appropriate power cabinet into cabinet and connect it to electrical box and receptacle.

3.Exterior blower may not exceed 6.0 Amp rating.

4.Run 2-wire plus ground power cable from the remote blower to wiring box on 10" round discharge plate.

5.Connect downdraft wiring to power cable from remote blower. Wire black to black, white to white, and green to green or bare wire.

6.Replace wiring box cover.

7.Plug the downdraft's power cord into outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.

All Units

"R" MODEL

DOWNDRAFT

1. Align the cooktop with the downdraft and fasten cooktop in place.

Note: Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent is raised and lowered.There should be a gap of 1/32" - 1/16" between the back of the cooktop and the front of the downdraft cover.

REMOTE

CONTROL

COUNTERTOP

Note:

The downdraft remote control must be mounted into the coun- tertop, at least 4" from cook top or range top edge.

8

Image 8
Contents To Reduce the Risk of a Range TOP Grease Fire Intended for Domestic Cooking onlyEvacuate and Call the Fire Department Interior Blower Installation Exterior Blower Installation Electrical SpecificationsPlanning Take MeasurementsPlan the Ductwork Side View Downdraft With VIDV500 Interior BlowerSide View Downdraft With Round Elbow For connection To VEDV900 or VEDV1200Plan the Cabinet Cutouts Plan the Wiring Interior Blower InstallationPrepare the Downdraft Important Location of Electrical OutletCUT Countertop Opening Before Cutting Hole Cabinet for Ductwork Install DuctworkMount the Unit Install Electrical Wiring Install CooktopBy a qualified persons in accordance with all Applicable codes and standardsInstallation of Remote Control Switch Backside Remote Switch Template Supply before cleaning and/or servicing unit OperationUSE and Care UP / DOWN-----RaisesBUILT-IN Rear Downdraft Warranty Specifications subject to change without notice F20126Destiné À LA Cuisine Domestique Seulement Avertissement VIDV500 intérieur, VEDV900 extérieur, ou VEDV1200 extérieurPréparation Prise DES MesuresTous les appareils SpécificationsPrise DES Mesures Suite Préparation DES ConduitsVUE DE Côté DE LA Hotte Avec Ventilateur Intérieur VIDV500 VUE DE Côté DE LAInstallation du ventilateur intérieur Sortie À GaucheSortie À Droite DE Découper L’ARMOIRE Pour LESImportant Position DE LA Prise ÉLECTRIQUE  Préparation DU CâblagePréparation DE LA Hotte Modèle DE Ventilateur Dimensions VIDV500 Découpage DU ComptoirTous les modèles Tion Ronde DEInstallation DE L’UNITÉ Installation DES ConduitsAvant DE Découper L’AR Moire Pour LES Conduits Assurez-vous que les solives duSurface DE Cuisson Installation DE LACâblage Électrique Installation DE LA Télécommande Bord DU ComptoirArrière DU Gabarit DE LA Télécommande Fonctionnement Utilisation ET EntretienAvertissement Coupez toujours le courant Avant de nettoyer ou d’entretenir l’appareilGarantie DES Hottes Encastrées

RVDD336R, CRVDD330R, CRVDD336R, CRVDD345R, RVDD345R specifications

The Viking CRVDD336R, RVDD345R, RVDD336R, CRVDD330R, and RVDD330R represent a series of advanced HVAC units designed to provide efficient cooling and heating solutions for a variety of commercial and residential applications. These models stand out due to their innovative technologies, energy efficiency, and user-friendly features.

One of the principal characteristics of these units is their robust design, enabling them to withstand harsh environmental conditions while maintaining performance consistency. Each model features a high-performance compressor and a well-engineered fan system that promotes optimal airflow. This ensures that indoor spaces are kept at comfortable temperatures while minimizing energy consumption.

Energy efficiency is a key highlight of the Viking line. Many of these models come equipped with inverter technology, which adjusts the compressor speed based on the cooling or heating demand. This not only lowers energy consumption but also reduces wear and tear on components, extending the lifespan of the system.

Additionally, the Viking CRVDD and RVDD series incorporate advanced control systems that enhance user experience. These controls allow for precise temperature settings and programmable schedules, providing flexibility to adapt to varying occupancy patterns. Moreover, some units are compatible with smart home systems, enabling remote access and management through mobile applications.

In terms of installation, these models are designed for versatility. They can be installed in various configurations, including ducted and ductless options, making them suitable for different building layouts. Their compact size also means they can fit in tight spaces while still providing powerful heating and cooling capabilities.

Maintenance is made easy with these units. Users can perform regular checks and service with minimal hassle, thanks to accessible components designed for quick inspections and replacements. Many models feature self-diagnosis capabilities, alerting users to potential issues before they escalate, further minimizing downtime.

Overall, the Viking CRVDD336R, RVDD345R, RVDD336R, CRVDD330R, and RVDD330R units are engineered to meet the demanding needs of today’s users. Their combination of efficiency, flexibility, and advanced technology positions them as excellent choices for anyone looking to upgrade their HVAC systems. With a strong focus on performance and sustainability, these models are an investment in comfort and reliability for years to come.