VENTILATION
Designer
Installation Requirements
DTWS Slim Traditional | DTWN Tall |
Wall Hood | Traditional Ledgeless |
| Wall Hood |
Proper installation/ducting is extremely important to ensure maximum performance. Use a qualified and trained installer.
DUCTING
•Check with a qualified and trained installer or local codes for makeup air requirements, if any.
•Max. duct run length
o For 300 – 1,200
o For 1,500
o For general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer.
UTILITY REQUIREMENTS
o Straight runs and gradual turns are best; for example, each 90° elbow is equivalent to 5’ – 10’ (1.52 – 3.05 cm) of straight run.
•7” (17.8 cm) round duct for 300 – 600 CFM; 10” for 900 – 1500 CFM
o Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
GAS
Not applicable
ELECTRICAL
•Hardwire direct with
•120 VAC/60 Hz
•Max. amp usage (rating includes recommended ventilator kit
PLUMBING
Not applicable
Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly overstated.
Model
Ventilator Kits
Interior Exterior
Duct Size
Interior Exterior
Max. Amps
Interior Exterior
DTWS3049 | DIV300/440 | DEV900 | 7” (17.8 cm) | 10” (25.4 cm) | 1.7/3.2 | 6.6 |
DTWS3649 | DIV300/440 | DEV900 | 7” (17.8 cm) | 10” (25.4 cm) | 1.7/3.2 | 6.6 |
DTWS4249 | DIV440 | DEV900 | 7” (17.8 cm) | 10” (25.4 cm) | 3.2 | 6.6 |
DTWS4849 | DIV880 | DEV1200/1500** | 10” (25.4 cm) | 10” (25.4 cm) | 5.6 | 4.3/5.1 |
DTWN3048 | VIV300/600/1200* | VEV900/1200* | 7” (17.8 cm) | 10” (25.4 cm) | 2.4/4.6/6.6 | 6.6/3.9 |
DTWN3648 | VIV300/600/1200* | VEV900/1200* | 7” (17.8 cm) | 10” (25.4 cm) | 2.4/4.6/6.6 | 6.6/3.9 |
DTWN4248 | VIV600/1200* | VEV900/1200* | 7” (17.8 cm) | 10” (25.4 cm) | 4.6/6.6 | 6.6/3.9 |
DTWN4848 | VIV1200* | VEV1200/1500** | 10” (25.4 cm) | 10” (25.4 cm) | 7.0 | 4.3/5.1 |
*A 1,200 CFM interior- or
**It is recommended that the 1,500 CFM ventilator be used with longer duct runs.
Note: Maximum amp rating for hoods includes recommended ventilator kit rating. All products must be hard wired with
P L A N N I N G A N D D E S I G N G U I D E | R E L E A S E D 1 2 / 1 / 0 7 |
V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1 | © 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE |