Troubleshooting/Fault Codes (For Dishwashers built prior to 05/26/10. Date code is listed on serial tag.)

 

FLASH

 

 

FAULT

 

ACTION

s

 

y

 

 

 

 

 

n

 

 

 

 

 

 

a

l

m

 

 

 

 

 

P

a

o

 

 

 

 

 

m

a

e

 

 

 

/

n

 

 

 

s

in

 

 

 

t

o

o

ns

 

 

 

o

c

h

 

 

 

 

r

 

 

 

Ri

 

 

 

P

N

E

C

 

 

 

X

 

 

 

 

 

Drain Timeout

1.

Turn water on at the sink and run garbage disposal to verify that sink is not clogged.

 

 

 

 

 

 

 

2.

Verify that dishwasher drain hose is not clogged or kinked.

 

 

 

 

 

 

 

3.

If draining into disposal, verify that plug has been removed from disposal.

 

 

 

 

 

 

 

4.

Verify that hose has a high loop, per installation guide.

 

 

 

 

 

 

 

5.

Verify dishwasher is level front to back and side to side.

 

 

 

 

 

 

 

6.

Verify filters are not clogged.

 

 

 

 

 

 

 

Reset Unit and try again. If problem persists, contact service.

 

 

 

 

 

 

 

 

 

X

X

 

 

 

 

Fill Timeout

1.

Verify water supply to dishwasher is turned on.

 

 

 

 

 

 

 

2.

Verify that fill line is not kinked.

 

 

 

 

 

 

 

3.

Verify that dishwasher is level front to back and side to side.

 

 

 

 

 

 

 

4.

Turn water on at sink and verify there has not been a decrease in water pressure.

 

 

 

 

 

 

 

Reset Unit and try again. If problem persists, contact service.

X

X

X

 

 

 

Flood Sensor Disconnect

Reset Unit and try again. If problem persists, contact service.

X

 

X

 

 

 

Temperature Sensor Disconnect

Reset Unit and try again. If problem persists, contact service.

X

 

X

 

X

X

Cycle Error (Motor Control Data Processor)

Reset Unit and try again. If problem persists, contact service.

X

 

 

 

X

 

Motor Control Communication Error

Reset Unit and try again. If problem persists, contact service.

X

 

 

 

X

X

Motor Control Status Error

Reset Unit and try again. If problem persists, contact service.

X

 

 

 

 

X

Diverter Error

Reset Unit and try again. If problem persists, contact service.

X

X

X

 

X

X

Cycle Error (Error Handler)

Reset Unit and try again. If problem persists, contact service.

 

X

X

 

 

 

Pan Flood

Reset Unit and try again. If problem persists, contact service.

 

X

X

 

X

 

Huba Disconnect

Reset Unit and try again. If problem persists, contact service.

 

X

X

 

X

X

Cycle Error (Circulate)

Reset Unit and try again. If problem persists, contact service.

 

X

 

 

X

 

UI-MC Communication Error

Reset Unit and try again. If problem persists, contact service.

 

X

 

 

X

X

Cycle Error (Fill)

Reset Unit and try again. If problem persists, contact service.

 

X

 

 

 

X

Sensor Error

1.

Verify that the dishwasher is level front to back and side to side.

 

 

 

 

 

 

 

2.

Verify that drain hose has high loop, per installation guide.

 

 

 

 

 

 

 

Reset Unit and try again. If problem persists, contact service.

 

 

 

 

 

 

 

 

 

 

X

 

 

 

Counter Error (UI)

Reset Unit and try again. If problem persists, contact service.

 

 

X

 

X

 

High Level Error

1.

Verify items in rack are properly retained so that they can not turn over.

 

 

 

 

 

 

 

Reset Unit and try again. If problem persists, contact service.

 

 

X

 

X

X

Cycle Error (Drain)

Reset Unit and try again. If problem persists, contact service.

 

 

X

 

 

X

Circulate Timeout (Includes Diverter)

Reset Unit and try again. If problem persists, contact service.

 

 

 

 

X

 

State Error (UI)

Reset Unit and try again. If problem persists, contact service.

 

 

 

 

X

X

Cycle Error (Main)

Reset Unit and try again. If problem persists, contact service.

 

 

 

 

 

X

Low Level Error

1.

Verify that no dishes have turned over and are holding a significant amount of water.

 

 

 

 

 

 

 

2.

Verify drain hose has a high loop, per page X in installation guide.

 

 

 

 

 

 

 

Reset Unit and try again. If problem persists, contact service.

 

 

 

 

 

 

 

 

 

NOTE: To reset unit, press and hold the “START” button for four seconds.

Product Care

34

35

Image 18
Contents Viking Use & Care Manual Congratulations Table of Contents Important Safety InstructionsImportant Safety Instructions Features Features Cycle Data ModelFeatures Cycles Preparing Dishes Changing a ProgramWashing Recommendations CommentsRack Adjustments Loading the DishwasherLoading Silverware Basket Silverware/Cutlery BasketDishwasher Detergent Storing the DetergentRinse Agent Wash TemperaturePower On Light Energy Saving TipsMaintenance Water HardnessMaintenance Troubleshooting To Clean FiltersPoor Dishwashing Results Problem Possiblecause AND/OR Remedy Care Flash Fault Action Pan Flood Sensor Disconnect Five Year Limited Warranty Service Information WarrantyOne Year Full Warranty Motor/Pump and Water DistributionIfetimeL Limited Warranty Ninety 90 Dayresidential Plus Warranty

F20631E specifications

The Viking F20631E is a remarkable light aircraft, specifically designed to balance performance with comfort, making it an excellent choice for both recreational pilots and serious aviators. As part of Viking's renowned line of aircraft, the F20631E showcases a blend of traditional design principles and contemporary technologies that enhance safety and efficiency.

One of the standout features of the Viking F20631E is its robust airframe, built from advanced materials that ensure durability while minimizing weight. This design contributes to improved fuel efficiency and excellent handling characteristics, critical for both short trips and longer excursions. The aircraft operates with a maximum takeoff weight of 2,600 pounds, allowing for a considerable payload capacity, ideal for carrying passengers or cargo.

The F20631E is powered by a dependable engine, specifically designed to deliver reliable performance across various altitudes and conditions. With a powerful, fuel-efficient engine, the aircraft can soar to cruising altitudes of around 10,000 feet, offering faster travel times and a more comfortable flying experience. In addition, the impressive climb rate means the aircraft can achieve altitude quickly, enhancing its performance during takeoff and ascent.

One of the most notable technologies integrated into the F20631E is its advanced avionics system. Featuring a state-of-the-art glass cockpit, pilots benefit from an intuitive layout that provides vital flight data at a glance. This modern system includes multifunction displays, GPS navigation, and autopilot capabilities, which not only improve the overall flying experience but also increase safety margins by reducing pilot workload.

Comfort is also a significant consideration in the design of the F20631E. The cabin is spacious, accommodating up to six passengers, with ergonomic seating and large windows that create a pleasant environment. The thoughtful layout ensures that passengers can enjoy a comfortable flight, making it suitable for longer journeys.

In summary, the Viking F20631E encapsulates a balance of innovative technologies and classic design, resulting in an aircraft that excels in performance, safety, and comfort. With its advanced avionics, efficient power system, and comfortable cabin, it presents an enticing option for both personal and business aviation, appealing to a wide range of flying enthusiasts. This aircraft stands as a testament to Viking's commitment to delivering quality and reliability in aviation.