Wolf MWD30-2F/S, MWD30-2U/S manual OL F Drawe R Microwave

Page 3

W OL F DRAWE R MICROWAVE

GRO UND ING I NST RU C TI ON S

Read all instructions before using this appliance to reduce the risk of burns, electric shock, fire, injury to persons or exposure to excessive microwave energy.

PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

Do not attempt to operate this microwave oven with the door open since open-door operation can result in harmful exposure to microwave energy. It is important not to defeat or tamper with the safety interlocks.

Do not place any object between the microwave oven front face and the door or allow soil or cleaner residue to accumulate on sealing surfaces.

Do not operate the microwave oven if it is damaged. It is particularly important that the oven door close properly and that there is no damage to the: (1) door (bent), (2) hinges and latches (broken or loosened), (3) door seals and sealing surfaces.

The microwave oven should not be adjusted or repaired by anyone except properly qualified service personnel.

This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordi- nances. In the event of an electrical short circuit, grounding reduces risk of electric shock by providing an escape wire for the electric current.

Improper use of the grounding plug can result in a risk of electric shock.

ELEC TR IC AL RE QU IR EM E N TS

The electrical requirements are a 120 volt 60 Hz, AC only, 15 amp. or more protected electri- cal supply. It is recommended that a separate circuit serving only this appliance be provided.

A short power-supply cord is provided to reduce risk of becoming entangled in or tripping over a longer cord. DO NOT USE AN EXTENSION CORD. If the power supply cord is too short, have a qualified electrician or servi- ceperson install an outlet near the appliance.

NOTES:

1)If you have any questions about the grounding or electrical instructions, consult a qualified electrician or serviceperson.

2)Neither Wolf nor the dealer can accept any liability for damage to the oven or personal injury resulting from failure to observe the correct electrical connection procedures.

CO NTA CT

IN FO RMA TI ON

Wolf Customer Service:

800-332-9513

Website:

wolfappliance.com

3

Image 3
Contents USE & CAR E Guide Thank YOU OL F Drawe R Microwave Impo Rtant Safe TY Inst Ruction S AN D Precautions To Reduce the Risk of Fire in the Oven Cavity INF ORM Ation YOU NEE D to Know General Safety OLF WAR RAN TY Drawe R Micr Owave F E Atur ESTOU CH CO NT ROL Panel TOU CH CO NTR OL PanelDI O O R T V I NT ER F E RE NCE Turn foods over once during microwav Stir foods from outside to center of dishHow to use aluminum foil in your drawer microwave Use these utensils for safe microwave cooking and reheatingFollowing coverings are ideal Before the drawer microwave can be used, follow these steps TI MERST OP/ CLE AR Suppose you want to defrost for 5 minutes at 30% To SE T PO WE R LE VE LSE NSO R C OO King Senso R C Ooking Casserole dish lidTouch START/ADD Minute pad SE NSO R Popcorn SE Nsor Reheat Sensor PopcornSensor Reheat Cabbage Fresh Vegetables SoftBroccoli Brussels SproutsRice Baked PotatoesGround Meat Fish, SeafoodDE FRO ST Bone-in Poultry Defr OST G UideSteaks, Chops Boneless PoultryFrozen Rolls, Muffins RE HE ATRE HE AT GUI DE Fresh Rolls, MuffinsFE Atures Multipl E SE Quence CO O KI NG Touch Micro Warm padHE LP Featu RE ADD M I N UT E To LO CK To turn reminder off To turn sound off Touch SETUP/HELP padTo restore sound Touch SETUP/HELP pad To turn reminder signal back onTouch START/ADD Minute pad. Enter To select Demo ModeTo cancel Demo Mode SE TU P / HEL PClea NI NG and C are Do not use abrasive or harsh cleaners orDrawer microwave light Part of all of drawer microwave does not operateFood in drawer Microwave is not heatedBEF or E CAL Ling F O R Servi CE Wolf Appliance Products Limited Warranty 13 5 TIN SE B 508 MR R0

MWD30-2F/S, MWD30-2U/S specifications

The Wolf MWD30-2U/S and MWD30-2F/S models are innovative heating solutions designed to cater to various domestic and commercial heating needs. These wall-mounted gas condensing boilers embody cutting-edge technology, ensuring efficiency, reliability, and high-performance heating.

One of the standout features of the MWD30-2U/S and MWD30-2F/S models is their impressive energy efficiency rating. By utilizing advanced condensing technology, these boilers maximize heat extraction from the fuel, significantly reducing energy consumption and associated costs. They boast an efficiency level of over 90%, making them environmentally friendly and cost-effective heating solutions.

Both models are equipped with a robust heat exchanger, which plays a crucial role in enhancing the heat transfer process. The stainless steel construction of the heat exchanger ensures durability and longevity, enabling the units to perform optimally over extended periods. This construction also aids in minimizing the risk of corrosion, ensuring consistent heat output.

The Wolf MWD30-2U/S and MWD30-2F/S models come with a user-friendly interface, allowing for easy operation and monitoring. The digital display provides real-time information on the boiler's performance, including temperature settings and operational status. This feature empowers users to make informed adjustments and maintain comfort levels efficiently.

In terms of installation flexibility, these boilers are designed for various configurations, making them suitable for different spaces and layouts. Their compact size allows for easy fitting in limited spaces, such as utility rooms or basements. Furthermore, with a range of flue options available, these models can be adapted to meet the specific requirements of any installation site.

Another vital characteristic is the exceptional safety features incorporated into the MWD30-2U/S and MWD30-2F/S units. These models have built-in safety mechanisms, including pressure monitoring and overheat protection, ensuring reliable operation while maintaining peace of mind for users.

In conclusion, the Wolf MWD30-2U/S and MWD30-2F/S models stand out in the modern heating market, combining advanced technology with essential user-friendly features. Their high efficiency, durable construction, flexibility in installation, and comprehensive safety measures make them an excellent choice for those seeking reliable and effective heating solutions. Whether for residential or commercial applications, these boilers truly represent the next generation of heating technology.