GRIDDLES MOUNTED ON STANDS WITH CASTERS

GRIDDLES MOUNTED ON STANDS WITH CASTERS

 

Griddles mounted on stands with casters must use a

 

flexible connector (not supplied) that complies with the

 

Standard for Connectors for Movable Gas Appliances

 

ANSI Z21.69•CSA6.16, and a quick-disconnect device

 

that complies with Gas Fuel, ANSI Z21.3•CSA6.9. In

 

addition, adequate means must be provided to limit

 

movement of the appliance without depending on the

 

connector and the quick-disconnect device (or its

 

associated piping) to limit appliance movement. Attach

 

the restraining device at the rear of the griddle as

 

shown in Fig. 1.

Fig. 1.

If disconnection of the restraint is necessary, turn off the gas supply before disconnecting. Reconnect the restraint prior to turning the gas supply on and returning the griddle to its installation position.

Note: Casters are only supplied on a griddle stand. If the griddle is moved for any reason the griddle should be re-leveled (see LEVELING in this manual).

STANDS

The griddle has an optional 25” high by 30” deep by 24”, 36”, 48”, 60” or 72” wide stainless steel stand with casters. The two front casters lock. The stand includes a top shelf with marine edges style lip and a lower shelf.

CUTTING BOARDS

Refer to the installation instructions provided with the cutting board kit.

GAS CONNECTIONS

CAUTION: Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.

Use a ¾” NPT gas supply line for the griddle inlet, located at the rear of the griddle. All of flexible and semi-rigid gas supply lines must comply with the applicable ANSI standard. To ensure maximum operating efficiency this appliance must be connected with a gas supply line of solid pipe or a commercial type Flexible Connector with the net inside diameter (I.D.) as large as or larger than the gas pipe inlet on this appliance. Codes require that a gas shutoff valve must be installed in the gas line upstream of the griddle.

WARNING: PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.

After checking for leaks all lines receiving gas should be fully purged to remove air.

- 5 -

Image 5
Contents Heavy Duty Gas Griddles INSTALLATION & OPERATION MANUAL FORMODELS MLS AGM24 ML-135236-AGM24 AGM36 ML-135237-AGM36 AGM48 ML-135238-AGM48FOR YOUR SAFETY IMPORTANT FOR YOUR SAFETYIN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICEINSTALLATION INSTALLATION, OPERATION AND CARE OF HEAVY DUTY GAS GRIDDLES GENERALModel Number of BurnersLOCATION INSTALLATION CODES AND STANDARDSThe griddle must be installed in accordance with STANDS GRIDDLES MOUNTED ON STANDS WITH CASTERSCUTTING BOARDS GAS CONNECTIONSFLUE CONNECTIONS GAS PRESSURE REGULATOR INSTALLATIONTESTING THE GAS SUPPLY SYSTEM BEFORE FIRST USE OPERATIONSEASONING THE GRIDDLE CONTROLS AGT ModelsZONE COOKING USING THE GRIDDLEZONE 300FCLEANING A CHROME GRIDDLE PLATE AFTER EACH USE CLEANING THE GRIDDLEAFTER EACH USE ONCE PER DAYPILOT ADJUSTMENT ADJUSTMENTSLEVELING CALIBRATION AGT Models onlySERVICE AND PARTS INFORMATION MAINTENANCELUBRICATION VENTPOSSIBLE CAUSES TROUBLESHOOTINGPROBLEM