Wolf AGT72 Operation, Before First Use, Seasoning The Griddle, CONTROLS AGT Models, AGM Models

Page 7
OPERATION

OPERATION

WARNING: THE GRIDDLE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING.

BEFORE FIRST USE

The griddle is shipped covered with a protective coating. Remove this film only when the griddle plate is being cleaned prior to its first cooking use. Use a non-corrosive, grease dissolving commercial cleaner, following the manufacturer’s directions. Rinse thoroughly and wipe dry with a soft clean cloth. Clean all accessories.

SEASONING THE GRIDDLE

Season the griddle to avoid possible surface corrosion before first use, and after every cleaning. Heat griddle to a low temperature (300-350°F) and apply a small amount of cooking oil – about one ounce per square foot of surface. Use a soft lint-free cloth to spread the oil over the entire griddle surface to create a thin film. Wipe off any excess oil with a cloth. Repeat the procedure until the griddle has a slick, mirror-like finish.

CONTROLS

AGT Models

Each 12” section of the griddle is independently controlled by a thermostatic valve. Turn the thermostat(s) to the desired setting.

NOTE: The burner is ALWAYS on for an AGT model griddle, which may cause griddle temperatures to exceed set point during periods of low usage.

AGM Models

Each 12” section of the griddle is heated by a burner with an manual infinite control valve. Adjust the valve position to the desired setting.

EXTENDED SHUTDOWN

1.Shut off the main gas supply valve.

2.Apply a heavy coat of oil over the griddle plate to inhibit rust.

- 7 -

Image 7
Contents AGM24 ML-135236-AGM24 AGM36 ML-135237-AGM36 AGM48 ML-135238-AGM48 INSTALLATION & OPERATION MANUAL FORHeavy Duty Gas Griddles MODELS MLSATTEMPT TO OPERATE THIS DEVICE IMPORTANT FOR YOUR SAFETYFOR YOUR SAFETY IN THE EVENT OF A POWER FAILURE, DO NOTNumber of Burners INSTALLATION, OPERATION AND CARE OF HEAVY DUTY GAS GRIDDLES GENERALINSTALLATION ModelThe griddle must be installed in accordance with INSTALLATION CODES AND STANDARDSLOCATION GAS CONNECTIONS GRIDDLES MOUNTED ON STANDS WITH CASTERSSTANDS CUTTING BOARDSTESTING THE GAS SUPPLY SYSTEM GAS PRESSURE REGULATOR INSTALLATIONFLUE CONNECTIONS CONTROLS AGT Models OPERATIONBEFORE FIRST USE SEASONING THE GRIDDLE300F USING THE GRIDDLEZONE COOKING ZONEONCE PER DAY CLEANING THE GRIDDLECLEANING A CHROME GRIDDLE PLATE AFTER EACH USE AFTER EACH USECALIBRATION AGT Models only ADJUSTMENTSPILOT ADJUSTMENT LEVELINGVENT MAINTENANCESERVICE AND PARTS INFORMATION LUBRICATIONPROBLEM TROUBLESHOOTINGPOSSIBLE CAUSES