PROBLEM

PROBLEM

Heat does not come on when the thermostat is turned on

Pilot burner will not light

Pilot burner will not stay lit

Fat appears to smoke excessively

Food sticks to griddle or burned around edges or contains dark specs

Food under-cooked inside

Food tastes greasy or has objectionable off-flavor

Noticeable build-up of gum on griddle

TROUBLESHOOTING

POSSIBLE CAUSES

1.Problem with thermostat. (Call for service)

2.Pilot burner not lit. (Call for service)

3.Problem with gas valve (Call for service)

1.Manual gas valve not turned on.

2.Obstructed pilot orifice. (Call for service)

3.Pilot gas turned off at pilot. (Call for service)

4.Problem with pilot valve. (Call for service)

1.Obstructed or wrong size pilot orifice. (Call for service)

2.Gas supply not purged of air. (Call for service)

3.Air blowing pilot out. (Call for service)

4.Problem with pilot valve (Call for service)

1.Temperature set too high.

2.Moisture in food may be turning into steam

1.Temperature set too high.

2.Griddle surface requires cleaning and/or seasoning.

3.Surface under food not covered with enough cooking oil.

1.Temperature set too high.

2.Food not cooked for long enough time.

1.Food itself may have off-flavor.

2.Food stored improperly before cooking.

3.Too much griddle fat used.

4.Temperature set too low.

1.Temperature set too high.

2.Griddle surface needs cleaning and/or seasoning.

3.Too much griddle fat used.

- 12 -

Image 12
Contents INSTALLATION & OPERATION MANUAL FOR Heavy Duty Gas GriddlesMODELS MLS AGM24 ML-135236-AGM24 AGM36 ML-135237-AGM36 AGM48 ML-135238-AGM48IMPORTANT FOR YOUR SAFETY FOR YOUR SAFETYIN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICEINSTALLATION, OPERATION AND CARE OF HEAVY DUTY GAS GRIDDLES GENERAL INSTALLATIONModel Number of BurnersINSTALLATION CODES AND STANDARDS The griddle must be installed in accordance withLOCATION GRIDDLES MOUNTED ON STANDS WITH CASTERS STANDSCUTTING BOARDS GAS CONNECTIONSGAS PRESSURE REGULATOR INSTALLATION TESTING THE GAS SUPPLY SYSTEMFLUE CONNECTIONS OPERATION BEFORE FIRST USESEASONING THE GRIDDLE CONTROLS AGT ModelsUSING THE GRIDDLE ZONE COOKINGZONE 300FCLEANING THE GRIDDLE CLEANING A CHROME GRIDDLE PLATE AFTER EACH USEAFTER EACH USE ONCE PER DAYADJUSTMENTS PILOT ADJUSTMENTLEVELING CALIBRATION AGT Models onlyMAINTENANCE SERVICE AND PARTS INFORMATIONLUBRICATION VENTTROUBLESHOOTING PROBLEMPOSSIBLE CAUSES