Wolf DD45I, DD45R dimensions Wolf Cooktop Ventilation Recommendations, CTWH30 CTWH36

Page 9

Planning Information

Wolf Cooktop Ventilation Recommendations

C O O K T O P V E N T I L A T I O N C F M R E C O M M E N D A T I O N S

Cooktop Hoods, Downdrafts and Pro Hoods

 

 

 

 

 

 

CTWH30

CTWH36

IH4227

DD30

DD36

DD45

Pro Hoods

 

 

 

 

 

 

 

 

Electric Cooktops

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model CT15E

215*

215*

215*

215*

 

150*

215*

 

 

 

 

 

 

 

 

Model CT30E

450

600

600

500

 

350

600

 

 

 

 

 

 

 

 

Model CT30EU

450

600

600

 

 

 

600

 

 

 

 

 

 

 

 

Model CT36E

 

600

600

 

500

 

600

 

 

 

 

 

 

 

 

Model CT36EU

 

600

600

 

 

 

600

 

 

 

 

 

 

 

 

 

CTWH30

CTWH36

IH4227

DD30

DD36

DD45

Pro Hoods

 

 

 

 

 

 

 

 

Gas Cooktops

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model CT15G

215*

215*

215*

215*

 

150*

215*

 

 

 

 

 

 

 

 

Model CT30G

450

600

600

500

 

350

600

 

 

 

 

 

 

 

 

Model CT36G

 

600

600

 

500

 

600

 

 

 

 

 

 

 

 

 

CTWH30

CTWH36

IH4227

DD30

DD36

DD45

Pro Hoods

Modules

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model CT15I

215*

215*

215*

215*

 

150*

215*

 

 

 

 

 

 

 

 

Model IG15

215*

215*

215*

 

 

 

215*

 

 

 

 

 

 

 

 

Model IS15

215*

215*

215*

 

 

 

215*

 

 

 

 

 

 

 

 

Model IF15

215*

215*

215*

 

 

 

215*

 

 

 

 

 

 

 

 

Model IM15

215*

215*

215*

215*

 

150*

215*

 

 

 

 

 

 

 

 

*Use these requirements to determine total CFM when installing multiple cooktops or modules.

CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW). Additional CFM may be required for long duct runs.

C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S

Downdraft Systems

 

 

Blower Description

Blower Number

Downdraft Models

 

 

 

 

500

CFM Internal

Included with (I) Models

DD30I / DD36I / DD45I

 

 

 

 

1100

CFM In-Line

BLOWER-110IL (808332)

DD30R / DD36R / DD45R

 

 

 

 

900

CFM Remote

BLOWER-90REM (801641)

DD30R / DD36R / DD45R

 

 

 

 

1200

CFM Remote

BLOWER-120REM (801642)

DD30R / DD36R / DD45R

 

 

 

 

1500

CFM Remote

BLOWER-150REM (804701)

DD30R / DD36R / DD45R

 

 

 

 

Adjustable discharge. 31/4" (83) x 10" (254) duct for internal blower, no transition required. 31/4" (83) x 14" (254) duct for in-line and remote blowers. TRANS-14-10 required for remote blowers.

Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking product. Always consult a qualified HVAC Engineer for specific applications.

Dimensions in parentheses are in

millimeters unless otherwise specified.

9

Image 9
Contents Models DD45I and DD45R Downdraft Systems E R a L L D I M E N S I O N S A T U R E SD E L O P T I O N S Specification SO W E R O P T I O N S C E S S O R I E SM E N S I O N S C a T I O N O F E L E C T R I C a LInstallation N O T E S C T I N G C O N S I D E R a T I O N S 12 MIN L F B L O W E R a S S E M B L I E S Wolf Ventilation RecommendationsCTWH30 CTWH36 Wolf Cooktop Ventilation Recommendations