Planning Information
Models DD45I and DD45R Downdraft Systems
M O D E L O P T I O N S
Downdraft with 500 CFM |
|
Internal Blower Included | DD45I |
Downdraft Only — |
|
Remote Blower Required | DD45R |
Control module, top cover, mounting brackets, DIN connector and mounting hardware included with the downdraft.
For Model DD45R see
B L O W E R O P T I O N S
1100 | CFM | 808332 |
900 CFM Remote Blower | 801641 | |
1200 | CFM Remote Blower | 801642 |
1500 | CFM Remote Blower | 804701 |
Refer to the Wolf Cooktop Ventilation Recommendations chart at the end of this section.
A C C E S S O R I E S
Transitions in various sizes
S P E C I F I C A T I O N S
Overall Width |
| 451/2" (1156) |
Overall Height (above countertop) | 91/16" (230) | |
Overall Depth |
| 2 3/8" (60) |
Duct Size (Model DD45I) |
| 31/4" (83) x 10" (254) |
Duct Size (Model DD45R) |
| 31/4" (83) x 14" (356) |
Discharge |
| Adjustable |
|
| |
Electrical Supply Requirements | 110/120 V AC, 60 Hz | |
|
| 15 amp dedicated circuit |
|
| |
Power Cord | 21/2' (.8 m) power cord with | |
|
| |
|
|
|
Shipping Weight |
| 85 lbs (39 kg) |
|
|
|
Specifications are subject to change without notice.
Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.
C O U N T E R T O P C U T- O U T
251/8" MIN
(638) FLAT COUNTERTOP SPACE
|
|
|
|
|
| 23/4" (70) | ||||||
|
|
|
| 42" (1067) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||||||
|
|
| COOKTOP |
|
|
|
| 191/4" | ||||
|
|
|
| |||||||||
|
|
|
| WIDTH | (489) | |||||||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
| 21/2" MIN |
| |||||
|
|
|
|
|
| (64) |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dimensions in parentheses are in |
|
millimeters unless otherwise specified. | 3 |