ELECTRICAL CONNECTIONS (Stacked Ovens)
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Make sure that the electrical power supply agrees with the specifications on the oven data plate, the wiring diagram on the oven, and with Electrical Data, page 5.
1.Wires to connect both ovens are provided with each oven. Carefully route these leads from the top oven through the bushing (supplied with the stacking kit) through the electrical access knockout holes common to both ovens.
2.Connect wires X, Y, and Z from the upper oven to the lower oven per the wiring diagram using wire nuts provided. Attach the power supply conduit to the bottom of the lower oven. Connect the power supply leads to the line side of the terminal block on the bottom oven.
3.Finally, inspect and check all wiring and terminal connections for tightness and proper routing away from any moving parts (relay solenoid core), or pinch points (cover on oven frame).
4.Refer to reference drawing 426986 supplied with the stacking kit for electrical connection instructions.
5.Refer to instructions supplied with the stacking kit for marking the combined electrical load information to the electrical data plate of the bottom oven.
BEFORE FIRST USE (All Models)
Before using the oven for the first time, it must be burned off to release any odors that might result from heating the new surfaces in the chamber.
1.Using a clean damp cloth, wipe the inside of the oven, including the racks.
2.Close the oven doors, turn the Master Switch ON, turn the Thermostat to 300°F (149°C) and allow the oven to cycle for 6 to 8 hours before turning the Master Switch OFF.