Installation Instructions For Natural Gas Conversion
(Kit Part No. 1173865)
This kit is designed for conversion to Natural Gas.
|
|
|
|
|
|
| Natural Gas Orifice Kits and Sizes |
|
|
|
|
|
| ||||
Table 1 |
|
|
|
|
|
| Elevation Above Sea Level |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| 0 to 2000 ft |
|
| 2001 to 4000 ft |
| 4001 to 5000 ft |
| 5001 to 6000 ft |
| 6001 to 7000 ft |
| 7001 to 8000 ft |
| 8001 to 9000 ft |
| 9001 to 10000 ft | |
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| Orifice Drill # |
| Orifice Drill # |
| Orifice Drill # |
| Orifice Drill # |
| Orifice Drill # |
| Orifice Drill # |
| Orifice Drill # |
Model Number | Orifice Drill # | Kit Number |
|
|
|
|
|
|
|
| |||||||
PGAA, PGMD (All Sizes) | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGAD, PGME (All Sizes) | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGX3, PDX3 (All Sizes) | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGC***K040F, GPCM**K040 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGC***K060F, GPCM**K060 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGC***K080F, GPCM**K080 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGC***K100F, GPCM**K100 | 41 | 1173865 |
|
| 43 |
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
PGC***K120F, GPCM**K120 | 42 | 1173865 |
|
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
| 47 |
PGC***K140F, GPCM**K140 | 42 | 1173865 |
|
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
| 47 |
PGF***K040F, GPFM**K040 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGF***K060F, GPFM**K060 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGF***K080F, GPFM**K080 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGF***K100F, GPFM**K100 | 41 | 1173865 |
|
| 43 |
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
PGF***K120F, GPFM**K120 | 42 | 1173865 |
|
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
| 47 |
PGF***K140F, GPFM**K140 | 42 | 1173865 |
|
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
| 47 |
PGS***K040F, GPSM**K040 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGS***K060F, GPSM**K060 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGS***K080F, GPSM**K080 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGS***K100F, GPSM**K100 | 41 | 1173865 |
|
| 43 |
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
PGS***K120F, GPSM**K120 | 42 | 1173865 |
|
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
| 47 |
PGS***K140F, GPSM**K140 | 42 | 1173865 |
|
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
| 47 |
PGF3**040 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGF3**060 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGF3**080 | 44 | 1173863 |
|
| 45 |
| 46 |
| 47 |
| 47 |
| 48 |
| 48 |
| 49 |
PGF3**100 | 41 | 1173865 |
|
| 43 |
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
PGF3**120 | 42 | 1173865 |
|
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
| 47 |
PGF3**140 | 42 | 1173865 |
|
| 43 |
| 43 |
| 44 |
| 44 |
| 45 |
| 46 |
| 47 |
Note: "**" or "***" may be any combination of numbers and/or letters in the model number. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Note: The orifice sizes in the chart above derate the input rate at 4% per 1000 feet above sea level for altitudes exceeding 2000 feet above sea level. |
|
|
|
|
|
|
|
| |||||||||
Natural gas data is based on .60 specific gravity, a heating value of 1030 Btu/cubic foot, and 3.5 "W.C. manifold pressure. |
|
|
|
|
|
|
|
|
|
| |||||||
For fuels with different specific gravity and/or different heating values, consult the National Fuel Gas Code ANSI Z223.1 - 2002/NFPA |
|
|
|
|
|
|
|
| |||||||||
National Standard of Canada, Natural Gas and Propane Installation Code CSA |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Note: If converting from LP gas to Natural gas at altitudes exceeding 2000 feet above sea level, | conversion kit (Part | ||||||||||||||||
orifice (Part # 5032110) is also required. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Parts List, Kit # 1173865 |
|
| |
Description | Part # | Qty | |
Burner Orifice #41 | 1096942 | 7 |
|
Burner Orifice #42 | 1011351 | 7 |
|
Pilot Orifice (0.018) | 503211 | 1 |
|
Honeywell Conv. Kit #396222 | 1172952 | 1 |
|
Label, Natural Gas Conversion | 1173866 | 1 |
|
Label, Field Conversion | 1009678 | 1 |
|
Instructions | 462 06 1211 00 | 1 |
|
SAFETY REQUIREMENTS |
|
| |
Recognize safety information. This is the | ! . |
When you see this symbol in instruction manuals be alert to the potential for personal injury.
Understand the signal words DANGER,WARNING, or CAUTION. These words are used with the
Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment. Untrained service personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to or shipped with the appliance and other safety precautions that may apply.
Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) ANSI
These instructions cover minimum requirements and conform to existing national standards and safety codes. In some instances, these instructions exceed certain local codes and ordinances, especially those that may not have kept up with changing residential construction practices. We require these instructions as a minimum for a safe installation.
| 462 06 1211 00 |
3/17/06 |