Replacing Filters
The grease filters should be removed and cleaned at least once a month. The charcoal filters cannot be washed and should be replaced every six to twelve months. Do not operate the microwave oven without the filters in place. See “Assistance or Service” to reorder filters. See “General Cleaning” for cleaning instructions.
WARNING
Electrical Shock Hazard
Disconnect power before removing filters.
Replace all panels before operating.
Failure to do so can result in death or electrical shock.
To Remove:
1.Unplug microwave oven or disconnect power.
2.Remove the grease filters by pushing up and sliding to the side. Pull tab down until the filter drops out.
1
2
1.Push up
2.Tabs
3.Remove charcoal filters by pushing the back of each filter away from you until the front of the filter slides off the front lower lip. Swing the front of the filter down and slide out.
1
2
3
1.Upper lip
2.Spring
3.Lower lip
To Replace:
1.Replace charcoal filters by positioning the filter at the back of the opening and resting it on the springs. While pushing the filter into the springs, position the front of filter between the front upper and lower lips.
2.Replace grease filters by inserting one end into the frame. Swing other side up and slide into position.
3.Plug in microwave oven or reconnect power.
Replacing Cooktop Light
The cooktop light is a 10W
To Replace:
1.Unplug microwave oven or disconnect power.
2.Remove the bulb cover mounting screw, and carefully remove cover.
1
1.Mounting screw
3.Remove the old bulb.
4.Replace bulb, using a tissue to handle the bulb, or wearing cotton gloves. Do not touch bulb with bare fingers.
5.Replace bulb cover and mounting screw.
6.Plug in microwave oven or reconnect power.
16